16 INSTALLATION
WARNING
• Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack
in the line so that the range can be moved if
servicing is ever necessary.
• The power supply cord and plug should
not be modified. If it will not fit the outlet,
have a proper outlet Installed by a qualified
electrician.
• Using an extension cord to connect the
power is prohibited. Connect the power
cord and plug directly.
• Electrical ground is required on this
appliance.
• Make sure that the power cord is not
pinched by the range or heavy objects.
Failure to do so can result in serious burns or
electrical shock.
Specified power-supply-cord kit rating
Range rating, watts
120/240
120/208
volts
volts
3-wire
3-wire
8,750 -
7,801 -
40 or 50 A
16,500
12,500
16,501 -
12,501 -
22,500
18,500
3, 4 - Wire electrical wall Receptacle
4 Wire receptacle (14-50R)
3 Wire receptacle (10-50R)
Connecting the Power Cord
The rear access cover must be removed. Loosen the
two screws with a screwdriver. The terminal block will
then be accessible.
Access cover
Diameter (inches)
Specified
of Range
rating of
connection
power
Opening
supply-
cord kit,
Power
Conduit
amperes
cord
1
/
1
"
3
8
50
1
/
1
3
"
4
Use the cord/conduit connection plate to install the
power cord or conduit. Leave the connection plate
as installed for power cord installations. Remove the
connection plate for conduit installations and use the
smaller 1
/
in. (2.8 cm) conduit hole instead of the
1
8
1
/
in. (3.5 cm) power cord hole.
3
8
1
/
" (2.8 cm) Conduit
1
8
1
/
" (3.5 cm) Cord
3
8
Remove the conduit connection plate
For power cord installations, hook the strain relief
over the 1
/
3
8
below the rear of the oven. Insert the power cord
through the strain relief and tighten it.
/
"
1
8
Assembling power cord strain relief at the 1
/
3
"
8
For conduit installations, insert the conduit strain
relief in the 1
the conduit through the body of the strain relief and
fasten the strain relief with its ring.
Ring
Body
Assembling conduit cord strain relief at the 1
in. (3.5 cm) power cord hole located
/
in. (2.8 cm) conduit hole. Then install
1
8
Conduit
connection
plate
Power cord
3
/
" opening
8
Cord/
Conduit
connection
plate
Conduit
/
" opening
1
8