Sharp LC-19SK24U Service Manual page 40

Table of Contents

Advertisement

LC-19SK24U/U-W
LC-19SB24U/U-W
LC-19SB14U
LC-19D44U
NOTE: If want to set all item to ON,please set to RUN in ADJUST PROCESS.
4.5 TEMP Adjustment
4.5.1
Receive US-10ch(JPN-8ch) the standard color bar signal
4.5.2
See if the "YDATA" reading (maximum) on Adjustment Process Page 1 is within the range in the
follow table. If not, adjust the "TEMP ALL" setting on the same page to have the "YDATA" reading
(maximum) within this range.
SETTING VALUE (NTSC)
Refence
(Adjustment Process Menu Page 1)
0
1
2
3
4
0
D
V
P
1
1
T
A M P
2
Y
D
A
3
T
A M P
4
T
A M P
5
N
T
S
6
P
A
L
7
P
A
L
19K24U P18-57.indd
40
Signal: color BAR (SATURATION 75%)
Setting: 28: XGA
H: 48.36KHz
SYNC: OFF
Note: Please use the color Bar of SATURATION
2 Adjusting AUTO GAIN-OFFSET in page 5 of DVP(M2-PC)to RUN .
When "AUTO GAIN-OFFSET OK" appears , this adjustment is complete
MODEL
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
1
L
T
A
1
H
A
L
L
C
T
A M P
1
-
M
T
A M P
-
N
T
A M P
V: 60Hz
A3KL19SK24U
96-100
40
9
6
9
8
1
0
0
O
F
F
7
7
6
4
6
4
2007-8-15
15:30:48