Summary of Contents for Certa CTPSWAVINVA

  • Page 1 3000W PURE SINE WAVE POWER INVERTER (12V TO 240V) CTPSWAVINVA...
  • Page 3: Safety And Warnings

    SAFETY & WARNINGS Before first use, read all safety warnings and instructions in this user guide. Retain this user guide for future reference. It is high recommended to have this product installed by a licenced electrician or auto- electrician. • Keep out of reach of children. •...
  • Page 4 • Operating the inverter outside the temperature range of -15C to 35C will reduce the output efficiency. • To extend the lifespan of the inverter, it is recommended to keep the load usage under 85% of the rated output level. •...
  • Page 5 OVERVIEW AC socket AC socket Power indicator (GREEN) Fault indicator (RED) ports Remote Power port switch DC input “+” Ground terminal DC input “-” terminal...
  • Page 6: Installation

    INSTALLATION WARNING: Ensure all DC connections are tight. Loose connections can cause overheating and pose a hazard. Only use high-quality copper wire and keep the cable in a suitable length. Choosing a Location When choosing a location for the power inverter, keep in mind the following recommendations: •...
  • Page 7 Connecting the Inverter Mount the inverter using 4mm screws appropriate for the surface the inverter will be on. Orient the inverter so that objects cannot fall into the ventilation holes. Ensure the inverter power switch is in the OFF position. Using the table below as a reference, select the correct cable size, then measure, cut and terminate the required cable length.
  • Page 8: Operation

    OPERATION Ensure the inverter is switched OFF before connecting any devices. Ensure that the devices to be powered by the inverter are in a safe and functional condition. Check the electrical requirements of the devices by examining the compliance plate or sticker. If unsure, contact the manufacturer for guidance. It's important to note that the inverter must be able to produce the required amount of continuous power.
  • Page 9: Troubleshooting

    TROUBLESHOOTING Power Fault indicator indicator Alarm Problem Solution output (GREEN) (RED) Cease use, recharge the battery Low input Continuous or replace with a charged voltage alarm battery. Low input Cease use, recharge the battery Beeping voltage shut or replace with a charged down.
  • Page 10: Specifications

    SPECIFICATIONS Input voltage DC 13V Input Operating voltage range DC 11-15V No-load output voltage AC 230V +/- 10V Load output voltage AC 215V~240V Output frequency 50 ± 3Hz Output USB output (total max) DC 5V MAX 2100mA Continuous power 1500W Peak power 3000W Output wave...
  • Page 11 Over-load shutdown Yes (1550-1800W) Reduce the load in the rated power range. Over-load Over-load recovery Restart inverter recovery work. Or Wait 6 - 7 minutes for the inverter to recover automatically. Over-temperature protection Yes When the temperature inside the Over temp inverter decreases to the set point, Over- temperature recovery the inverter will recover...