Summary of Contents for Rice Lake TranSend 7000 Series

  • Page 1 MSI TranSend 7000 Series Single and Multiple Channel Transmitters and Receivers Technical Manual April 19, 2023 PN 167375 Rev E...
  • Page 2 All information contained within this publication is, to the best of our knowledge, complete and accurate at the time of publication. Rice Lake Weighing Systems reserves the right to make changes to the technology, features, specifications and design of the equipment without notice.
  • Page 3 April 19, 2023 Established revision history; added RF regulatory information Table i. Revision Letter History Technical training seminars are available through Rice Lake Weighing Systems. Course descriptions and dates can be viewed at www.ricelake.com/training or obtained by calling 715-234-9171 and asking for the training department.
  • Page 4: Table Of Contents

    Inputs / Outputs ................37 Rice Lake continually offers web-based video training on a growing selection of product-related topics at no cost.
  • Page 5 6.0 Specifications ............... . . 51 Technical training seminars are available through Rice Lake Weighing Systems.
  • Page 6 MSI TranSend 7000 Series Rice Lake continually offers web-based video training on a growing selection of product-related topics at no cost. Visit www.ricelake.com/webinars www.RiceLake.com Visit our website...
  • Page 7: Introduction

    Overview The MSI TranSend 7000 Series offers a wireless option in systems where it would be difficult to have a load cell cable. Replacing the cable with an RF link, the output will be calibrated to match the device that the cable was connected to. A single MSI TranSend 7000 Series transmitter or receiver can be used to communicate with a ScaleCore-based remote display or indicator.
  • Page 8: Standard Features

    MSI TranSend 7000 Series Standard Features • Works with any basic digital weight indicator • Excitation to load cell(s) provided by the transmitter, not the indicator • Each transmitter/receiver set is individually paired for communication • Auto-sleep mode - power down during non-use, power up with weight change •...
  • Page 9: Safety

    Do not operate or work on this equipment unless this manual has been read and all instructions are understood. Failure to follow the instructions or heed the warnings could result in injury or death. Contact any Rice Lake Weighing Systems dealer for replacement manuals.
  • Page 10: Msi-7000 Front Panel

    MSI TranSend 7000 Series MSI-7000 Front Panel Serial Wi-Fi 802.11 Port 802.15.4 FHSS Set Point Set Point Power Output Input Figure 1-2. MSI-7000 Front Panel Item No. Description Power Input – Located on the side of the unit Setpoint 1-3 Connections – Located on the side of the unit Type of Power Source –...
  • Page 11: Msi-7001 Front Panel

    Power Input – Located on the side of the unit; Type is checked Serial Port – Located on the side of unit; Pre-set at 9600 baud and 8-N-1 Table 1-2. MSI-7001 Front Panel Controls © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 12: Msi-7000Hd Front Panel

    MSI TranSend 7000 Series MSI-7000HD Front Panel CHANNEL CHANNEL RELAY RELAY CHANNEL CHANNEL POWER IN Figure 1-4. MSI-7000HD Front Panel Item No. Description Setpoint 1-3 Connections – Located on the side of the unit Power Input – Located on the side of the unit Setpoint LEDs Green –...
  • Page 13: Msi-7001Hd Front Panel

    Communication Ports – Comm Port 1 is pre-set at 9600 baud and 8-N-1; Comm Port 2 is pre-set at 38400 baud and 8-N-1 Load Cell Connectors - Located on the side of the unit. Table 1-4. MSI-7001HD Front Panel Controls © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 14: Installation

    Unpacking and Assembly Immediately after unpacking, visually inspect the contents to ensure all components are included and undamaged. If any parts were damaged in shipment, notify Rice Lake Weighing Systems and the shipper immediately. Connect Load Cell Cables 2.2.1 MSI-7001 TranSend If using the optional pre-wired cable, refer to the load cell wiring guide table for connecting the cable to the load cell.
  • Page 15: Msi-7000 Transend And Msi-7000Hd

    – Signal 2 Load Cell 2 + Signal 2 – Excitation Shared + Excitation – Signal 1 Load Cell 1 + Signal 1 Shield Figure 2-3. MSI-7001HD Load Cell to Terminal Block Connection © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 16: Connect Power

    MSI TranSend 7000 Series Connect Power 2.3.1 MSI-7001 TranSend 1. Connect the power source to the MSI-7001 TranSend. 7001 Power Input Wiring, 7-36VDC Version 7001 Power Input Wiring, 5-6VDC Version +VIN 6VDC Battery Connector Power Input Cable 120VAC Power Power Input Cable Adapter Connector Figure 2-4.
  • Page 17: Plc Wiring Diagrams

    External Loop 20mA Output Max R 24mA Output Max R wiring wiring Voltage Input shunt shunt None 625Ω 520Ω 750Ω 625Ω 1.05kΩ 875Ω 1.35kΩ 1.125kΩ 1.65kΩ 1.375kΩ Table 2-3. Current Compliance Table © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 18: Relays

    MSI TranSend 7000 Series Relays The MSI-7000 TranSend can be equipped with three Form C Coil relays for process control or safety related systems. The MSI- 7000HD comes standard with three relays. Relays are installed and wired out to 3 pins on a M12 connector.
  • Page 19: Radio Compliance

    All radio options meet FCC and international radio compliance per the certification information listed in this section. These modules may have additional international certifications that are not listed in this section. Please contact Rice Lake Weighing Systems if you require operation in a jurisdiction that is not listed. 2.8.1 802.15.4 (XBee 3 and XBee 3-PRO)
  • Page 20: Fhss (Frequency Hopper Spread Spectrum)

    ETSI Certified Antenna Options NOTE: To meet FCC licensing rules, use only antennas supplied or recommended by Rice Lake Weighing Systems. Antenna placement is critical to problem-free use of the system. • Ensure a relatively clear transmission path exists between the devices to be connected; Radio signals travel primarily by line of sight (LOS), obstructions between stations may degrade the system performance •...
  • Page 21: Available Antennas

    The mount includes 17' of low loss coax terminated in a TNC connector. YAGI Antenna For maximum range, a 14 dBi gain Yagi Antenna is available by special order. Please contact Rice Lake Weighing Systems for details. Corner Reflector Antenna Corner reflector antennas are often the best choice for a wall mounted antenna.
  • Page 22: 2.10 Mounting The Enclosure

    2.10 Mounting the Enclosure The MSI TranSend 7000 Series transmitters and receivers can be mounted either vertically or horizontally to a flat surface. If mounted inside an enclosure or I-beam, use the correct antenna for the environment and distance. Please call Rice Lake Weighing Systems, if assistance is needed to select an antenna, or reference the antenna selection guide in the appendix.
  • Page 23 45.49 mm 2.579" 1.24" 65.51 mm 31.50 mm 0.276" Bottom Ø 0.177" (4.50 mm) 7.01 mm Top Ø 0.382" (9.70 mm) 1.58" 39.88 mm Figure 2-10. Mounting Dimensions – MSI-7000 TranSend © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 24 MSI TranSend 7000 Series 8.10" 205.74 mm 7.529" 191.24 mm Center Distance 5.60" 142.24 mm 5.029" Bottom Ø 0.266" 127.74 mm (6.76 mm) Center Distance Top Ø 0.438" (11.13 mm) 1.50" 38.10 mm Figure 2-11. Mounting Dimensions – MSI-7000HD www.RiceLake.com...
  • Page 25 158.70 mm Center Distance 2.85" 72.39 mm Bottom Ø 0.201" 2.335" (5.11 mm) 59.31 mm Top Ø 0.375" Center Distance (9.53 mm) 1.688" 42.88 mm Figure 2-12. Mounting Dimensions – MSI-7001HD © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 26: Scalecore Connect

    3.1.2 Install Program To install: 1. Open the Rice Lake website and navigate to the and scroll to the ScaleCore Connect file. MSI software page 2. Download the ScaleCore Connect software to the computer. 3. Extract the zip file to generate the ScaleCore Connect folder.
  • Page 27: Connect Product To Computer

    . Connected devices display. 2. Select the device to configure and press 3.2.2 Device Profiles Section 3.3 on page 38 for the advanced setup of the device profiles. Figure 3-3. Device Profiles © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 28: Configuration

    – power source of current product User Defined Model NOTE: Only 6V Battery and 110V AC (AC and 7-36V) are valid option for the MSI TranSend 7000 series products. Figure 3-6. User Defined Model Selections – enter a name for the product User Model Name –...
  • Page 29 – select a number 1-16 Source Sensor ID – select unit to be used Unit Figure 3-8. DAC Unit Selection – select value type to be used Value Type Figure 3-9. Value Type Selections © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 30 MSI TranSend 7000 Series – enter min sensor value acceptable Min Sensor Value – enter max sensor value acceptable Max Sensor Value – check box is applicable Not Filtered Sensor Value – current calibration value DAC Offset – current calibration value DAC Gain –...
  • Page 31 – select a scan list number Scan List Number – select a remote device ID number Remote Device ID – select a source sensor ID number Source Sensor ID 3. Press to save. © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 32: Load Cells

    MSI TranSend 7000 Series 3.2.4 Load Cells The general load cell display allows the load cells’ parameters to be set to for each load cell connected to the connected device. Figure 3-16. Load Cell General Settings 1. Select , then...
  • Page 33 – select the drop threshold number from 0-100 Drop Threshold – select the rise threshold number from 0-100 Rise Threshold 3. Press to save. New settings will not take affect until power is cycled on the product. © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 34 Maintenance Section 3.3.6 on page 43 for the advanced setup of the maintenance settings. NOTE: Do not change these settings without consulting Rice Lake Weighing Systems or a local dealer. Figure 3-21. Maintenance Settings Calibration Records 1. Select...
  • Page 35: Calibration

    5. Enter the test weight value, then press 6. Press . The constant calibration number is displayed, document the number for use later if needed. 7. Repeat steps above for each load cell to be re-calibrated. © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 36 MSI TranSend 7000 Series Full Constant Calibration 1. Select , then Calibration Full C-Cal Load Cell 2. Press 3. Set the parameters. Unit Capacity 4. Press 5. Select the desired parameter, then press Countby 6. Ensure there is no weight on the load cell, then press 7.
  • Page 37: Inputs / Outputs

    Stream Print String Section 3.3.7 on page 44 for the advanced setup of the stream print string settings. NOTE: Do not change these settings without consulting Rice Lake Weighing Systems or a local dealer. 3.2.7 Monitors Select the view to be used for viewing the data from the product.
  • Page 38: Advanced Setup

    This section is a guide for the advanced setup of the product being read by the ScaleCore Connect program. The following setup instructions are for dealers or service technicians only. Please contact Rice Lake Weigh Systems or a local dealer for assistance before proceeding.
  • Page 39: Administration Menu

    , then Communications Select Stream Port 2. Select the port to be used from the drop down. Figure 3-30. Select Stream Port 3. Press to save and return to main page. © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 40 MSI TranSend 7000 Series Stream Port Setup To configure communications stream ports: 1. Select , then Communications Configure 2. Select the port to be configured and press Figure 3-31. Communication Setup 3. Set the option: • – Rate at which information is transferred through the port...
  • Page 41: Program

    3. Press , a file dialog box pops-up. 4. Select an app code file from the file dialog box, press , app code file is sent to the target device. © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 42 MSI TranSend 7000 Series Acquire Profile from Device ScaleCore Connect will acquire the profile from an attached device. Figure 3-34. Acquire Profile 1. Select from the drop down menu. Acquire Profile from Device Program 2. When prompted save the file to desired location.
  • Page 43: Device Profiles

    – select the sensor ID from 1-4 Sensor ID – select the lift threshold number from 0-100 Lift Threshold – select the drop threshold number from 0-100 Drop Threshold 3. Press to save. © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 44: Stream Print String

    MSI TranSend 7000 Series 3.3.7 Stream Print String Listeners Listeners feature controls the machine to machine communications interfaces. Figure 3-37. Listener Settings 1. Select , then Inputs / Outputs Stream Print String 2. Select the tab. Listeners 3. Enter the following parameters: –...
  • Page 45 Figure 3-39. Format Editor Use the buttons to create the string or type it into the formatter box. The maximum length for this print string is 18 characters. © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 46: Msi Mv Scale Calibration

    MSI TranSend 7000 Series MSI mV Scale Calibration Use the following instructions to calibrate an MSI TranSend 7000 Series receiver unit. The MSI mV Scale Calibration software can be downloaded from the Rice Lake Weighing Systems website. 1. Power on the transmitter and receiver units.
  • Page 47 8. Press 9. Enter the total scale capacity. Figure 4-4. Scale Capacity 10. Press 11. Remove all weight from the scale. Figure 4-5. Zero Calibration 12. When scale is stable, press © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 48 MSI TranSend 7000 Series Figure 4-6. Span Calibration 13. Load test weights onto the scale. 14. Enter the appropriate weight value in the weight dialogue box. 15. Press . Calibration Complete displays. Figure 4-7. Calibration Complete 16. Press to return to the calibration start display.
  • Page 49: Optional Rugged Remote

    The range may vary up to 100' or more depending on room conditions and line of sight. The RF modem in the MSI-7000 must be configured to accept communication from the Rugged Remote, contact Rice Lake Weighing Systems for pairing requirements.
  • Page 50: Power

    MSI TranSend 7000 Series 5.1.1 Power The Rugged Remote can be enabled to turn on and off the ScaleCore device it is paired remotely. The hold function must be enabled. NOTE: The Hold feature causes the device's modem to stay on and continuously draw from the battery, even when the device is turned off, resulting in decreased battery life.
  • Page 51: Specifications

    MSI-7000 TranSend: NEMA Type 4 (IP65), aluminum black powder coated (excludes wall cube model) MSI-7001 TranSend: NEMA Type 4 (IP65), aluminum black powder coated (excludes wall cube model) MSI-7000HD/MSI-7001HD: IP66, Milled Anodized Aluminum Additional RF Options Wi-Fi 802.15.4 FHSS Warranty One-year limited © Rice Lake Weighing Systems ● All Rights Reserved...
  • Page 52 MSI TranSend 7000 Series www.RiceLake.com Visit our website...
  • Page 54 © Rice Lake Weighing Systems Specifications subject to change without notice. 230 W. Coleman St. • Rice Lake, WI 54868 • USA U.S. 800-472-6703 • Canada/Mexico 800-321-6703 • International 715-234-9171 • Europe +31 (0)26 472 1319 April 19, 2023 PN 167375 Rev E...