  • Page 1 PRODUCT UPDATE V2 RELEASE HEAT PUMP CONTROLLER V2 MANUAL INSTALLATION OPERATION MAINTENANCE...
  • Page 2 This appliance may deliver water at high temperature. Refer to the Plumbing Code of Australia (PCA), local requirements and installation instructions to determine if additional delivery temperature control is required. Issue 01b | April 2023 Reclaim Energy | Owners/Installation Manual – Controller v2...
  • Page 3: Table Of Contents

    SECTION PAGE Product Update Before you Begin Installation First Time Commissioning Guide Installing the Reclaim Controller Introduction Setup Menu Wi-Fi Setup Status Display How to Extend the Modbus Cable How to Extend the Temperature Cable Owners/Installation Manual – Controller v2 | Reclaim Energy RECLAIMENERGY.COM.AU...
  • Page 4: Product Update

    As of April 2023, Reclaim Energy will launch the next generation of heat pump with some substantial improvements. Unless specified below, all other parameters/specifications are the same between V1 and V2 models. The two key changes are summarised in Table A and Table B below:...
  • Page 5 18-hour cycle (i.e. this is to ensure any legionella bacterial growth is controlled in a 24 hour cycle). Boost function Available Manuals Website Table B: Key updates on the Reclaim Energy controllers Owners/Installation Manual – Controller v2 | Reclaim Energy RECLAIMENERGY.COM.AU...
  • Page 6: Before You Begin Installation

    Remove ALL power sources before removing protective cover. The Reclaim Controller must be installed by a qualified person. Ensure suitable over-current protection and RCD protection for the Reclaim Controller is in place. Reclaim Energy | Owners/Installation Manual – Controller v2...
  • Page 7: First Time Commissioning Guide

    ↑ button or ↓ button to change the value of the Year/Month/Day. o press the ← button or → button to move the position of the blinking cursor. Owners/Installation Manual – Controller v2 | Reclaim Energy RECLAIMENERGY.COM.AU...
  • Page 8 OK button for 5 seconds. Purge mode is automatically turned off if the module is currently displaying heat pump Modbus error or other heat pump error code. Reclaim Energy | Owners/Installation Manual – Controller v2...
  • Page 9: Installing The Reclaim Controller

    INSTALLING THE RECLAIM CONTROLLER MOUNTING CONNECT TO HEAT PUMP • Fix mounting bracket to a solid structure with the • Connect the ring terminals of the Modbus cable to the screws and wall plug kit provided. Modbus Port of the Heat Pump •...
  • Page 10: Introduction

    INTRODUCTION V2 CONTROLLER The controller comes with • Modbus Cable 1.5m • Temperature Sensor 2.5m • Power Cable 1.5m Reclaim Energy | Owners/Installation Manual – Controller v2...
  • Page 11 Go to previous item in list Decrement value Down Go to next item in list Validate selection Change input type Boost (Wi-Fi password entry menu only) Table 11: Usage of keys in setup menus Owners/Installation Manual – Controller v2 | Reclaim Energy RECLAIMENERGY.COM.AU...
  • Page 12 T-off setting (59°C). The Boost mode can also be turned on and off via a momentary press of the boost button. When activated, temperature control mode is enabled, as above, signalling Reclaim Energy | Owners/Installation Manual – Controller v2...
  • Page 13: Setup Menu

    Figure 2-9: Mode 5, set timer 2 T-On temperature The input cursor will blink on the temperature; press the ▲ / ▼ keys to change the temperature and press ENTER to confirm. Owners/Installation Manual – Controller v2 | Reclaim Energy RECLAIMENERGY.COM.AU...
  • Page 14 18 hour cycle, the system will automatically run to meet the legionella requirement 18 hours Figure 2-14: Mode 6, set timer 2 T-Off temperature after the last time that 59°C was reached. Reclaim Energy | Owners/Installation Manual – Controller v2...
  • Page 15 S E T L O C A T I O N S E T L O C A T I O N V I C V I C Figure 2-19: Set location Owners/Installation Manual – Controller v2 | Reclaim Energy RECLAIMENERGY.COM.AU...
  • Page 16 • The lists of Wi-Fi networks found is listed in order Figure 2-24: Wi-Fi network info of signal strength (strongest to weakest) and the network security type is also displayed; press the ▲ / ▼ keys to select the network. Reclaim Energy | Owners/Installation Manual – Controller v2...
  • Page 17 W I F I S E T T I N G S R E S E T O K R E S E T O K Figure 2-33: Wi-Fi settings reset Owners/Installation Manual – Controller v2 | Reclaim Energy RECLAIMENERGY.COM.AU...
  • Page 18 C E R T I D C E R T I D a b c d e 1 2 3 4 5 a b c d e 1 2 3 4 5 Figure 2-39: Certificate ID Reclaim Energy | Owners/Installation Manual – Controller v2...
  • Page 19: Wi-Fi Setup

    I N C O R R E C T Figure 3-3: Wi-Fi setup mode using LCD/keypad Figure 3-7: Wi-Fi password incorrect The controller then operates in OFFLINE mode. Wi-Fi can be setup later in the setup menu. Owners/Installation Manual – Controller v2 | Reclaim Energy RECLAIMENERGY.COM.AU...
  • Page 20 M y N e t w o r k 1 2 3 - 3 0 d B m W P A / 2 - 3 0 d B m W P A / 2 Figure 3-11: Wi-Fi networks’ information Reclaim Energy | Owners/Installation Manual – Controller v2...
  • Page 21 Wi-Fi configuration page automatically. o On some mobile devices, it may be necessary to click on a ‘Sign in’ prompt to open the configuration page, as shown below. Owners/Installation Manual – Controller v2 | Reclaim Energy RECLAIMENERGY.COM.AU...
  • Page 22 If an authentication error is reported, the message ‘WIFI PASSWORD INCORRECT’ will be shown on the controller’s display. Figure 3-17: Connection in progress Figure 3-19: Connection failed Reclaim Energy | Owners/Installation Manual – Controller v2...
  • Page 23 RECLAIM ENERGY MOBILE APP FOR APPLE & ANDROID ANDROID APP 1. Installation a) Go to the Play Store on the Android phone and search for “Reclaim Energy”. FREE APP b) Install the App and wait for installation to complete. RECLAIM ENERGY 2.
  • Page 24 Otherwise, click on ‘See more’ b) view of historic power consumption data. to open the device Wi-Fi settings page. c) Follow the instructions on the Wi-Fi configuration screen to complete the Wi-Fi connection setup. Reclaim Energy | Owners/Installation Manual – Controller v2...
  • Page 25 Locate the QR code sticker from the controller box and scan it in the App. • Once the controller information is saved, the App will connect to the controller and load its data. Owners/Installation Manual – Controller v2 | Reclaim Energy RECLAIMENERGY.COM.AU...
  • Page 26 Click Confirm to open the iPhone Settings. From here you will need to navigate to the Wi-Fi Settings. Reclaim Energy | Owners/Installation Manual – Controller v2...
  • Page 27: Status Display

    T A N K : 3 6 ¯ ¯ T O F : 5 9 T O F : 5 9 ¯ ¯ T A N K : 3 6 Figure 4-8: Heat pump 3 seconds ON maintain indicator Owners/Installation Manual – Controller v2 | Reclaim Energy RECLAIMENERGY.COM.AU...
  • Page 28 O P 5 : 2 = 9 A M - 1 2 P M O P 5 : 2 = 9 A M - 1 2 P M Figure 4-13: Operation mode 5 (User timers) Reclaim Energy | Owners/Installation Manual – Controller v2...
  • Page 29 The following faults can be displayed: WATER ERROR Eg-4 CIRCULATION SYSTEM FAILURE HEATING Eg-5 PUMP ERROR FAN MOTOR Eg-6 ERROR DISCHARGE Eg-7 ERROR Table 3: List of faults for Heat Pump V2 Owners/Installation Manual – Controller v2 | Reclaim Energy RECLAIMENERGY.COM.AU...
  • Page 30 S E N S O R F A U L T Figure 4-19: Tank sensor fault 4.5.3 MODBUS ERROR MESSAGE DISPLAYED GROUP ON LCD Eg-12 HEAT PUMP MODBUS ERROR Table 5: List of faults for Modbus Reclaim Energy | Owners/Installation Manual – Controller v2...
  • Page 31: How To Extend The Modbus Cable

    Replace the Modbus Cable by following the instructions Replace the Temperature Sensor Cable by following below: the instructions below: Switch off the mains power and disconnect the Reclaim Switch off the mains power and disconnect the Reclaim Controller and Heat Pump. Controller.