7. TECHNICAL DATA

Generator
Protection type:
Continuous rated power P
Maximum power P
(S2 5 min):
max
Maximum power P
(2 min):
max
Rated voltage U
:
rated
Rated current I
:
rated
Frequency F
:
rated
Drive engine design:
Displacement:
Max. power:
Fuel:
Tank capacity:
Engine oil:
Consumption at 2/3 load:
Weight:
Sound pressure level L
pA
Sound power level L
: /K uncertainty
WA
Power factor cos :
Power class:
Max. temperature:
Max. altitude (above mean sea level):
Spark plug:
Operating mode S1 (continuous operation)
The machine can be continuously operated with the quoted power output.
Operating mode S2 (temporary operation)
The machine may be temporarily operated with the quoted power output (5 min.). Afterwards the machine must
be stopped for a while to prevent it from overheating (5 min.).
GENERATOR
(S1):
rated
:
Synchronous
IP 23M
2100 W/230 V ~
2300 W/230 V ~
2400 W/230 V ~
2 × 230 V ~
9. 1 A (230V ~ )
50 Hz
4-stroke, air-cooled
212 cm
3
4. 1 5 kW / 5.6 hp
normal unleaded petrol (E10)
15 l
ca. 0.6 l
approx. 1.2 l/h
37 kg
73.36 dB(A)
96 dB (A)/1.53 dB(A)
1
G1
40°C
1000 m
LD F6RTC
13
EN
Technical data
USER MANUAL

Advertisement

Table of Contents
loading

Table of Contents