PRE-PLANNING CHECKLIST
THIS SECTION DEMONSTRATES THE PROPER INSTALLATION AND TESTING OF THE PLUG & PLAY TO LOW VOLTAGE SYSTEMS.
TO ENSURE PROPER INSTALLATION PLEASE USE THIS PRE-PLANNING CHECKLIST:
Recommended Tools:
General Plumbing Tools (Pipe Wrench, Crescent Wrench, Pipe Cutters, etc.)
Manometer (To test static & dynamic gas pressure)
Voltmeter (To check voltage & amperage to unit)
Gloves
Mini-Butane Torch
Cordless Drill
Dielectric Grease or Silicone (For waterproofing wire nuts)
Whistle-free Stainless Steel Flex Gas Hoses (TOP does not recommend using the standard yellow
corrugated flex gas hoses as those cause a loud persistent whistle sound to occur when using the fire
feature)
Ensure the location is free of combustibles (See section 11 for more information.)
Measure & record distances of gas piping & electrical conduit runs, these will be useful for calculating
gas pressure and proper wiring. The distance and wire gauge DIRECTLY affects the performance of the
Electronic Ignition Component.
The Fire Feature is delivered on a pallet via freight and placed in front of your home. Please have a team
of movers ready to help move the unit from the curbside/driveway to the desired location. ALWAYS
inspect the pallet for damage or missing pieces, if there is damage or missing pieces please DO NOT sign
for the pallet and call our support team immediately to help resolve any problems.
All fire features require a hollow area underneath the pan for serviceability of the unit, DO NOT FILL the
hollow basin with sand or any other media.
Gas Risers should come up to a maximum height of 2" from the ground and use a 90-degree fitting to
help reduce the basin height and allow for easy servicing.
TOP DOES NOT RECOMMEND to use the standard yellow corrugated gas flex hoses with its fire features,
TOP recommends to use a Whistle-Free Stainless Steel Gas Flex Hose in order to help eliminate any
whistling sounds.
Ensure you use the Home-run method for connecting multiple Electronic Ignition Component units, DO
NOT DAISY CHAIN these units.
Ensure you ordered the right gas type and ignition type for your installation.