Piper ARCHER II Pilot Operating Handbook page 58

Table of Contents

Advertisement

SECTION 3
PIPER AIRCRAFT CORPORATION
EMERGENCY PROCEDURES
PA-28-181, ARCHER II
If an electrical fire is indicated (smoke in the cabin), the master switch
should be turned OFF. The cabin vents should be opened and the cabin heat
turned OFF. A landing should be made as soon as possible.
NOTE
The possibility of an engine fire in flight is
extremely
remote. The procedure given is
general
and
pilot judgment
should
be the
determining
factor
for action
in such
an
emergency.
3.17 LOSS OF OIL PRESSURE
If engine stoppage occurs, proceed with Power Off Landing.
REPORT: VB-1120
ISSUED: JULY 2, 1979
3-12