Piper ARCHER II Pilot Operating Handbook page 275

Table of Contents

Advertisement

Disconnect Methods
The following conditions will cause the autopilot lo automatically disconnect:
e
Electrical power failure, including pulling the AUTOPILOT circuit breaker.
e
Intemal autopilot system failure (including internal AHRS failure).
The following pilot actions will cause the autopilot to disconnect:
e
Pressing the red AP DISC / TRIM INT button on the pilot's control wheel.
e
Actuating the manual electric trim swilch (if installed).
e
Pushing the AP Key on the GMC 507 mode controller when the autopilot is engaged.
e
Pulling the AUTOPILOT circuil breaker.
Figure 7-3: GMC 507 Control Unit (Reference Only)
4900
|
AFMS - GFC 500 Autopi
Page 7~4
in Piper PA-28 Series
190-02291-07 Rev. 5