Operation (Cont.); Flow Meter - Carlisle Ransburg IntelliFlow RM2 User Manual

Low and medium pressure
Table of Contents

Advertisement

EN

FLOW METER

The flow meter is a gear-type positive displacement meter specially designed for paint and will measure flow
up to 1900cc per minute. A sensor detects the movement of the inner gears and sends an electronic signal in
the form of a pulse to the controller.
Flow Meter Do:
Filter the paint with a minimum 100 mesh filter. Change filter screens regularly.
Use pressure regulators upstream from the flow meter to prevent false readings from fluctuating pump
pressure spikes.
Make sure the system is properly grounded and avoid electrical noise at the machine location.
Calibrate the flow meter cc's/pulse frequently. Even different batches of the same paint can have different
flow characteristics.
Store the meter filled with solvent.
Remove the tube/nut when removing the flow meter from the fluid panel (the flow meter is mounted to
the base of the color stack using a tube fitting).
Leave the flow meter inlet and outlet fittings intact.
Flow Meter Do Not:
Run the meter dry or spin the gears for a prolonged time with air only.
Leave the meter to sit or stagnate with air or water inside the flow meter.
Let the meter dangle by the cable.
Let the meter drop onto the floor.
Flow Meter Calibration
Perform flow meter calibration regularly as described on the next page. The A+B calibration will verify ratio
and flow meter calibration in one simple operation.