Example Definition Of Weekly Program; Example Keeping Of Constant Temperature - ELEKTROBOCK TS10 Manual

Thermoswitch socket
Table of Contents

Advertisement

EXAMPLE definition of weekly program

1. Set on 18°C (PA:r2)
2. Set on 23°C (PA:r3)
3. Select programming of whole week d1:7 (Prog)
4. 17:U1 assign time 6:00 and temperature
5. 17:U2 assigm time 9:00 and temperature
6. 17:U3 assign time13:00 and temperature
7. 17:U4 assign time 19:00 and temperature
8. Leave the programming mode by pressing button
and select AUTO mode.

EXAMPLE keeping of constant temperature

Fce
1. Press
button and choose with
-
/
2. By
buttons set the required temperature e.g. 5 °C.
+
3. This temperature will be kept till the further manual temperature change.
3. ANOTHER FUNCTIONS
Short-term change of temperature in AUTO mode:
By simple pressing of
change of required temperature. The socket will maintain this temperature up
to next temperature change as defined in the program.
Antifreeze protection:
If the room temperature is lower than 3 °C, TS10 switch on automatic the
connected device. As soon as the temperature rise the TS10 comes back to the
preset mode.
Function" OFF " :
Fce
-
/
Press
and by
and confirm by
. In this way, TS10 is permanently
i
switched off. In this mode, symbol OF:F and antifreeze temperature
3°C are showed alternatively on the display. For deactivation of this function
Fce
press
button and select different mode with using of
Note: in OFF mode is maintained the antifreeze temperature 3°C!
5
-
/
+
-
/
in AUTO mode it is possible to make a short-term
+
button select OF:F function
+
representation of
program course on LCD
function MANU and confirm
-
/
+
Mo - So
[h]
.
i
button.