Download Print this page

Troubleshooting; Specification - CAMDEN CM-419 Installation Manual

Request to exit motion detector

Advertisement

8.

TROUBLESHOOTING

9.

SPECIFICATION

PRODUCT NAME
DETECTION SYSTEM
MOUNTING HEIGHT
DETECTION
AREA
POWER SUPPLY
POWER CONSUMPTION
OUTPUT
WIRING CONNECTION
TEMPERATURE RANGE
MOUNTING POSITION
WEIGHT
APPEARANCE
ACCESSORIES
PATTERN
ADJUSTMENT RANGE
SENSITIVITY
LED
COVER
WINDOW
- 5 -
REX SENSOR (REQUEST TO EXIT SENSOR)
Passive Infrared
13 ft. (4m) Max
Single door or double door selectable
Wall mount
: Vertically 35 Degrees (8 steps)
Overhead mount : Vertically 20 degrees (5 steps)
Adjustable
12 to 24VDC (Non polarity)
or
12 to 24VAC (50Hz/60Hz)
40mA or less /DC
Dry contact relay 2C - 30V (DC) 1A or less / 125V
(AC) 0.6A or less
Operation
: One Shot
Hold time
: Adjustable Approx. 0.25sec. to 60 sec.
*Selectable relay operation
Green Operation : Synchronous dry contact relay
(LED )disabled
Terminals
+14 deg. F to +122 Deg. F (-10 Deg. C to +50 Deg. C)
Wall ceiling, on or under frame (Indoor)
5.95 oz (170g)
White or Silver
White
Tapping screws
Resister (82ohms, 3W) : 1pcs for AC 20 to 24V
Cover locking screw
-AC 20 to 24V use
resister supplied
70mA or less /AC
: 2 pc.
: 1 pc.