Advertisement

Quick Links

User manual
Installation
RAVEN 4000Intrusion Detection and Management System
RAVEN 4500/RAVEN 4300
RAVEN4000 Media Module
RAVEN 4500M-8T/RAVEN 4500M-8F/RAVEN 4500M-4T4F
RAVEN 4300M-8T/RAVEN 4300M-8F/RAVEN 4300M-4T4F
Installing RAVEN 4000 IDS
Technical support
Published on
01 10/2020
http:// hirschmann-it.support.belden.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Hirschmann It RAVEN 4000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Belden Hirschmann It RAVEN 4000

  • Page 1 User manual Installation RAVEN 4000Intrusion Detection and Management System RAVEN 4500/RAVEN 4300 RAVEN4000 Media Module RAVEN 4500M-8T/RAVEN 4500M-8F/RAVEN 4500M-4T4F RAVEN 4300M-8T/RAVEN 4300M-8F/RAVEN 4300M-4T4F Installing RAVEN 4000 IDS Technical support Published on 01 10/2020 http:// hirschmann-it.support.belden.com...
  • Page 2 The performance characteristics described herein shall be binding only upon the express consent of the parties at the time of signing the contract. This paper is produced by Belden Inc. within its capacity. Belden reserves the right to change the contents of this manual without prior notice. Belden does not guarantee the correctness or accuracy of the information in this manual.
  • Page 3: Table Of Contents

    Contents Safety guidelines About the manual Legend General equipment description Equipment name and product code 1.2.1 Basic device 1.2.2 Media module Equipment view Power supply Ethernet port 1.5.1 Console port attribute 1.5.2 USB Console port attribute 1.5.3 10/100/1000 Mbit/s twisted pair port 1.5.4 1000Base-X SFP optical interface attribute Display unit...
  • Page 4 Remove device 7 Technical data General technical data Dimension drawing EMC and immunity Network range Power consumption / power output Error! Bookmark not defined. 8 Delivery item, order number and accessories 9 Basic technical standards A More support Installing RAVEN 4000 IDS Published on 01 01/2020...
  • Page 5: Safety Guidelines

     Make sure there is no component to be repaired in the equipment. In case of any damage or failure to the equipment, off the power and return the equipment to Belden for inspection.  Qualification requirements for operators  Only qualified personnel are allowed to operate the equipment.
  • Page 6  Correct use Use the equipment only for the purposes specified in the catalog and technical instructions. Only external devices components recommended and permitted by the manufacturer can be used to operate the equipment. The correct and safe operation of this product depends on the correct operation, storage, assembly and installation during transport, as well as careful operation and maintenance procedures.
  • Page 7 Power cord diameter at the power supply voltage input shall be at least 0.75 mm²  (North America: AWG18). The cross section of the grounding conductor shall be the same as or larger than that  of the power cord. ...
  • Page 8 Special conditions for safe use  Install the basic equipment and modules in a suitable enclosure based on specific environmental conditions to provide at least IP54 protection according to the requirements of EN 60529.  Take measures to prevent instantaneous interference from exceeding 140% of the rated voltage at the voltage input.
  • Page 9  Equipment enclosure Only technicians authorized by the manufacturer are allowed to open the enclosure.  Keep vents open to ensure good air circulation.  Ensure a minimum of 3.94 inches (10 cm) of space in front of the enclosure vent. ...
  • Page 10 Stuttgarter Str. 45-51 72654 Neckartenzlingen Germany www.belden.com Warning! As Class A equipment, it may cause interference to the living area. In such case, the operator may need to take appropriate actions. Warning! When Ethernet cables are used in industrial environments, they must be shielded.
  • Page 11  LED or Laser Component LED or Laser Component conforming to IEC 60825-1 (2014): Class 1 laser products Class 1 LED products  FCC description: The equipment complies with Section 15 of FCC. The equipment shall be operated in line with the following two requirements: (1) the equipment causes no harmful interference;...
  • Page 12: About The Manual

    About the manual This user manual about “Installation” contains equipment instructions, safety instructions, display instructions, and other information required for equipment installation. Installing RAVEN 4000 IDS Published on 01 01/2020...
  • Page 13: Legend

    Legend The symbols used in this manual have the following meanings:  Item list  Work step  Subtitle Installing RAVEN 4000 IDS Published on 01 10 /2020...
  • Page 14: General Equipment Description

    Description General equipment description RAVEN4000 Intrusion Detection and Management System is a threat detection, analysis and management product that Hirschmann IT creates independently and owns completely independent intellectual property rights。The product has a high-precision detection capability for viruses, worms, Trojans, DDoS, scanning, SQL injection, XSS, buffer overflow, deception hijacking and other attacks, as well as network resource abuse (such as P2P upload/download, network games, video/audio, network stock trading) and other threats.
  • Page 15  Media module RAVEN 4500M-8T RAVEN 4500M-8F RAVEN 4500M-4T4F Installing RAVEN 4000 IDS Published on 01 10 /2020...
  • Page 16 RAVEN 4300M-8T RAVEN 4300M-8F RAVEN 4300M-4T4F You can select 1 media module. Media modules are provided as accessories. Please refer to “Order number” on Page 68. Installing RAVEN 4000 IDS Published on 01 01/2020...
  • Page 17: Equipment Name And Product Code

    Equipment name and product code The equipment name corresponds to the product code. 1.2.1 Basic device Order Product code Description number 5xGE TX ports, 1×RJ45 console port, 942999713 RAVEN 4500 1×extended slot 5xGE TX ports, 1×RJ45 console port, 942999714 RAVEN 4300 1×extended slot 1.2.2 Media module...
  • Page 18: Equipment View

    Equipment view :RJ45 Console Port :2×USB Port :MGT Port :10/100/1000M Adaptive Ethernet Port :Power sockets and power es at the rear of the chassis :Media Module Power supply Installing RAVEN 4000 IDS Published on 01 01/2020...
  • Page 19 You may use the power module to supply voltage to the equipment: See the “Power module” on page 17 for information about connecting supply voltage. Installing RAVEN 4000 IDS Published on 01 10 /2020...
  • Page 20: Ethernet Port

    Ethernet port You may use twisted pair or fiber optic (F/O) cables to connect terminal devices and other network segments to the equipment and the media module ports. 1.5.1 Console port attribute Attribute Description Interface standard Asynchronous EIA/TIA-232 Connector type RJ45 Baud rate 9600- 115200 (default as 9600)
  • Page 21: 1000Base-X Sfp Optical Interface Attribute

    Single mode optical fiber of multimode optical fiber See the “Command line interface user manual” for more information. You may download the manual on the product page of Hirschmann IT at https://hirschmann-it.support.belden.com. Installing RAVEN 4000 IDS Published on 01 10 /2020...
  • Page 22: Display Unit

    Display unit After the power supply voltage is set, the software will start automatically and complete initialization. And then the equipment performs self-test. All LED indicators will come on in this process. 1.6.1 Equipment status These LEDs provide information about the conditions that affect the operation of the equipment.
  • Page 23: Port Status

    1.6.2 Port Status These LEDs provide port information. Indicator Indicator Indicator color Status type name RJ45 Flashing: indicating data sending on serial port self-contained OFF: indicating no data sending on serial port Serial port yellow LED indicator RJ45 Build-in Flashing: indicating data receiving on serial port green LED OFF: indicating no data receiving on serial port ON: indicating successful connection establishment on...
  • Page 24: Management Interface

    Management interface 1.7.1 Console interface The serial interface is provided on RJ45 socket and thus you are allowed to establish the connection to the command line interface CLI and the system monitor. 1.7.2 MGT interface An MGT management interface is provided. Through this interface, users can configure access to the IDS Web interface using a PC (or laptop) with RJ45.
  • Page 25 Installation These devices are developed for use in commercial environments. At the time of delivery, the device is ready for operation. Perform the following work steps to install and configure the device:  Checking the package contents  Installing and grounding the device ...
  • Page 26 Installing and grounding the device Perform the following work steps:  Installing the device in the switch cabinet  Installing the device on a vertical flat surface  Grounding the device 2.2.1 Installing the device in the switch cabinet WARNING ELECTRIC SHOCK Install this device solely in a switch cabinet or in an operating site with restricted access, to which maintenance staff have exclusive access.
  • Page 27  Attach the mounting bracket to the switch cabinet. Figure 6: Installing the power module on a switch cabinet Installing RAVEN 4000 IDS Published on 01 10 /2020...
  • Page 28 2.6.1 Installing the device on a vertical flat surface WARNING FIRE RISK In case of vertical installation, install the device in the fireproof enclosure. Failure to follow this instruction can result in death, serious injury, or device damage. Perform the following work steps: ...
  • Page 29 2.6.2 Grounding the device WARNING ELECTRIC SHOCK Ground the device before connecting any other cables. Failure to follow this instruction can result in death, serious injury, or device damage. The device has the connection of the protective grounding wire. The device is grounded by the grounding screw and the power socket. Perform the following work steps: ...
  • Page 30 Installing the SFP transceiver (optional) Prerequisite: Exclusively use Hirschmann IT SFP transceivers. See “Accessories” on the page Error! Bookmark not defined.. Perform the following work steps:  Take the SFP transceiver out of the transport packaging, refer to figure 9 below.
  • Page 31 Operating the device Perform the following work step: Connect the power supply cable, refer to figure 12 below.   Enable the power supply. Figure 12: Connect the power supply Connecting the data cables Note the following general recommendations for data cable connections in an environments with high electrical interference levels: ...
  • Page 32 Make basic settings Note: Configuring two or more devices with the same IP address may lead to the network’s failure to function as expected. Install and maintain a program, to assign a unique IP address to each device in the network. IP parameters must be entered when the equipment is installed for the first time.
  • Page 33 Monitor ambient air temperature Please operate the equipment only below the specified maximum ambient air temperature. Please refer to “General technical data” on Page 49. The ambient air temperature is the air temperature at a distance of 2 inches (5 cm) from the equipment, specifically depending on the installation conditions of the equipment, for example, the distance of the equipment from other devices or other objects, and the output of adjacent equipment.
  • Page 34 You may view the information and download software on the product page of Hirschmann IT at https://hirschmann-it.support.belden.com  Depending on the pollution level in the operating environment, regularly check whether the ventilation slot in the equipment is blocked.
  • Page 35 Installing RAVEN 4000 IDS Published on 01 10 /2020...
  • Page 36: Remove

    Remove 6.1 Remove media module Follow the steps below:  Remove screws on the front panel of the media module.  Pull the media module out of the slot  Seal the media module slot on the basic device with a cover plate. ...
  • Page 37 Remove device Warning Electric shock Please disconnect all other cables before disconnecting the ground wire. Failure to comply with these guidelines may result in death, serious injury or equipment damage. Follow the steps below:  Disconnect the data cable.  Disable the supply voltage. ...
  • Page 38 Technical data 7.1 General technical data  Basic device Size Please refer to “Size diagram” on Page 40. Power supply Rated voltage range 100 VAC...240 VAC ,50 Hz...60 Hz Maximum conductor AWG12 (2.5 mm2) diameter Equipment ground Tighten torque 3.5~6.1 lb-in (0.4~0.7 Protective grounding...
  • Page 39 Dimension drawing  Basic device RAVEN 4500 Installing RAVEN 4000 IDS Published on 01 10 /2020...
  • Page 40 RAVEN 4300 Installing RAVEN 4000 IDS Published on 01 01/2020...
  • Page 41 EMC and immunity EMC interference emission Standard application EN 55032 Class A DNV GL Guide — FCC 47 CFR Part 15 Class A EN 61000-6-4 Conforming EN 55032 AC/DC Power Line Class A DNV GL Guide AC/DC Power Line — FCC 47 CFR Part 15 AC/DC Power Line Class A...
  • Page 42 EMC immunity Standard application Electromagnetic field EN 61000-4-3 80 MHz...1000 MHz 10 V/m 1000 MHz...6000 MHz 3 V/m IEEE 1613 80 MHz...1000 MHz — Fast transient (burst) EN 61000-4-4 AC/DC Power Line ±2 kV IEEE C37.90.1 EN 61000-4-4 Data cable ±1 kV IEEE C37.90.1 EN 61000-4-5...
  • Page 43 EMC immunity Standard application Damped vibration - AC/DC Power Line EN 61000-4-12 Cable / ground — IEEE C37.90.1 EN 61000-4-12 Cable / cable — IEEE C37.90.1 Damped oscillation - data cable EN 61000-4-12 Cable / ground — IEEE C37.90.1 EN 61000-4-12 Cable / cable —...
  • Page 44 Network range Note: The line length specified for the transceiver applies to the corresponding fiber data (fiber attenuation and BLP/dispersion). Product code Mode Optical BLPc/dispersio Wave length F/O cable length example MTS-SFP-1G-... attenuation TX/RJ Full Duplex -TX/RJ45... 100 m Negotiation 550 m (>...
  • Page 45 7.5 Power consumption / power output Name Maximum power consumption Power output Basic device RAVEN 4500 280 Btu (IT)/h RAVEN 4300 60 W 210 Btu (IT)/h Installing RAVEN 4000 IDS Published on 01 10 /2020...
  • Page 46 MTS-SFP-1G-LH+/LC 942 999 859 MTS-SFP-1G-BIDI-TypeA-LX/LC 942 999 860 MTS-SFP-1G-BIDI-TypeB-LX/LC 942 999 861 MTS-SFP-1G-LX+/LC-1550 942 999 862 a. You may access more information about certificates on the product page of Hirschmann IT (https://hirschmann-it.support.belden.com). Installing RAVEN 4000 IDS Published on 01 01/2020...
  • Page 47 Basic technical standards Name FCC 47CFR Part 15 Code of Federal Regulations IEC 60825-1 Laser product safety EN 55032 Electromagnetic compatibility of multimedia equipment - Emission requirements EN 62368-1 Information technology equipment - Safety - Part 1: General requirements EN 61000-3-2 Electromagnetic compatibility (EMC) –...
  • Page 48 The equipment usually meets the technical standards set forth in the latest version. Only when the equipment shell has the certification mark, it means that the equipment is certified to a specific standard. Installing RAVEN 4000 IDS Published on 01 01/2020...
  • Page 49 For the list of local telephone numbers and email addresses for you to get direct technical support from Hirschmann please visit: https://hirschmann-it.support.belden.com. The website also contains free knowledge base and software download section. Installing RAVEN 4000 IDS Published on 01 10 /2020...
  • Page 50 Installing RAVEN 4000 IDS Published on 01 01/2020...

Table of Contents