iTX Playout Appliance 2 Installation and Service Manual Important Safeguards and Notices This section provides important safety guidelines for operators and service personnel. Specific warnings and cautions appear throughout the manual where they apply. Please read and follow this important information, especially those instructions related to the risk of electric shock or injury to persons.
Page 4
Notices The presence of this symbol in or on Grass Valley product means that it complies with all applicable European Union (CE) directives. The presence of this symbol in or on Grass Valley product means that it complies with safety of laser product applicable standards. Warnings A warning indicates a possible hazard to personnel, which may cause injury or death.
Page 5
iTX Playout Appliance 2 Installation and Service Manual • When installing this equipment, do not attach the power cord to building surfaces. • Products that have no on/off switch, and use an external power supply must be installed in proximity to a main power outlet that is easily accessible. •...
Page 6
Notices Cautions for LCD and TFT Displays Excessive usage may harm your vision. Rest for 10 minutes for every 30 minutes of usage. If the LCD or TFT glass is broken, handle glass fragments with care when disposing of them. If any fluid leaks out of a damaged glass cell, be careful not to get the liquid crystal fluid in your mouth or skin.
Page 7
iTX Playout Appliance 2 Installation and Service Manual La marque C-CSA-US certifie que l’appareil visé a été testé par l'Association canadienne de normalisation (CSA) et reconnu conforme aux exigences applicables en matière de sécurité électrique en vigueur au Canada et aux États- Unis.
Page 8
Notices • Avant de procéder à toute opération d’entretien ou de dépannage, enlevez tous vos bijoux (notamment vos bagues, votre montre et autres objets métalliques). • Pour éviter tout risque d’incendie, utilisez uniquement les fusibles du type et du calibre indiqués sur l’équipement ou dans la documentation qui l’accompagne.
Page 9
iTX Playout Appliance 2 Installation and Service Manual • Assurez-vous que le châssis est relié électriquement à la terre par le cordon d'alimentation ou tout autre moyen disponible. • Portez un bracelet antistatique et assurez-vous qu'il est bien en contact avec la peau. Connectez la pince de masse à...
Page 10
Notices Safety of Laser Modules This equipment incorporates modules containing Class 1 lasers. These modules are certified by the manufacturer to comply with: – IEC/EN 60825-1 Safety of laser products – IEC 60950-1 Safety of information technology equipment Electromagnetic Compatibility This equipment has been tested for verification of compliance with FCC Part 15, Subpart B requirements for class A digital devices.
Overview of the iTX Playout Appliance 2 This document provides an overview of the product and guides you through the procedures for installing and setting up a new, factory-delivered iTX Playout Appliance 2 unit. This chapter provides information about the different models of iTX Playout Appliance 2 and the physical characteristics of the product, including system specifications and chassis components.
Overview of the iTX Playout Appliance 2 About the iTX Playout Appliance 2 About the iTX Playout Appliance 2 The iTX Playout Appliance 2 unit is a 1 RU rack mountable server designed to run iTX playout software, which processes audio and video content as required by scheduled events and delivers the SD or HD video output for one or two channels of iTX playout.
Page 15
iTX Playout Appliance 2 Installation and Service Manual System disk storage • 240 GB SSD RAID1 Network Adapter Card GVSP-3TB-WIN-2IO • Not equipped with a network adapter card. GVSP-3TB-WIN-2+2IO • Not equipped with a network adapter card. GVSP-3TB-WIN-4IO • Mellanox ConnectX®-4 Lx EN (option) GVSP-3TB-WIN-8IO •...
Page 16
Overview of the iTX Playout Appliance 2 System Specifications Operating system GVSP-3TB-WIN-2IO • Microsoft® Windows® Server 2008 R2 for Embedded Systems GVSP-3TB-WIN-2+2IO • Microsoft® Windows® Server 2008 R2 for Embedded Systems GVSP-3TB-WIN-4IO • Microsoft® Windows® Server 2012 R2 for Embedded Systems GVSP-3TB-WIN-8IO •...
iTX Playout Appliance 2 Installation and Service Manual Front Panel Components A removable bezel covers the front panel of the chassis and identifies the unit as an iTX Appliance 2. Behind the bezel are the unit’s front panel components, which includes two SSD drives, four SATA hard drives, two USB 3.0 ports and a control panel with power buttons and status monitoring lights.
Overview of the iTX Playout Appliance 2 SSD and SATA Drives SSD and SATA Drives The front panel provides access to ten drive carrier bays, which are populated by two SSD drives and four SATA hard drives; leaving four of the drive bays empty. Each drive carrier has an Activity LED and a Status LED.
iTX Playout Appliance 2 Installation and Service Manual Rear Panel Components The rear panel of the iTX Playout Appliance 2 chassis provides access to two power supply units, as well as the appliance’s input and output connectors. The following diagrams identify the rear panel components of the different iTX Playout Appliance 2 models: Fig.
Overview of the iTX Playout Appliance 2 Video Card Inputs and Outputs Fig. 1-4: Rear panel components of the GVSP-4TB-WIN-8IO Video Card Inputs and Outputs GVSP-3TB-WIN-2IO / GVSP-3TB-WIN-2+2IO Identifying the SDI video inputs and outputs on GVSP-3TB-WIN-2IO and GVSP-3TB-WIN- 2+2IO models is quite straightforward since the BNC connectors are labeled (SDI OUT, SDI IN and REF IN).
iTX Playout Appliance 2 Installation and Service Manual Corvid 44 Playout Type Port 1 Port 2 Port 3 Port 4 Port R Simulcast Ch A Ch B Ch A/B Ch A/B Input Output Output Input Input Main Main Main Second Dual Live Ch A Ch A...
Page 22
Overview of the iTX Playout Appliance 2 Power Supply Modules • : Indicates that the system power supply temperature has reached 36° C. Blinking amber The system will automatically power-down when the power supply temperature reaches 70° C and restarts when the power supply temperature goes below 60° C.
Installation and Start-up Procedures This chapter provides information about the installation and setup of the iTX Playout Appliance 2 unit. IMPORTANT - Please read this chapter in its entirety before beginning the installation procedure. Summary Installing the iTX Playout Appliance 2 Chassis in a Rack ....... 11 Cabling the iTX Playout Appliance 2 .
Installation and Start-up Procedures Cabling the iTX Playout Appliance 2 Cabling the iTX Playout Appliance 2 Once the iTX Playout Appliance 2 chassis is securely mounted in an equipment rack, you can make the required connections to the rear panel connectors. WARNING - Power cables Use the provided or designated power cables.
iTX Playout Appliance 2 Installation and Service Manual 6 Consult the SDI video card I/O configuration information on page 8 and take note of the connection requirements based on the intended playout type. Then connect the SDI input, SDI output and Reference cables to the SDI video card’s BNC or DIN connectors.
Page 26
Installation and Start-up Procedures Starting the iTX Playout Appliance 2...
Configuring the iTX Playout Appliance 2 This chapter provides instructions for the initial configuration of a factory-delivered iTX Playout Appliance 2 unit. Upon completing the initial configuration procedures, we recommend that you consult the iTX System Administrator Guide and iTX Output Server 2 Channel Configuration Guide for information on fully integrating the unit into your iTX system.
Page 28
Configuring the iTX Playout Appliance 2 Configuring Windows and System Settings d Move the adapter that you want to be the active connection to the top of the Connections list. e Ensure that the Internet Protocol Version 6 (TCP/IPv6) options are disabled in the Bindings list.
iTX Playout Appliance 2 Installation and Service Manual • Enable Turn on network discovery. • Disable Password protected sharing. (Workgroup only) 11 Disable Action notifications. a Use the Windows Start menu to open the Windows Control Panel. b Select System and Security > Action Center > Change Action Center Settings. c In the Security Messages section, uncheck the following options: •...
Page 30
Configuring the iTX Playout Appliance 2 Configuring iTX (GVSP-3T-WIN-2IO and GVSP-3TB-WIN-2+2IO) 1 Install iTX licenses. a Obtain the iTX license file from your Grass Valley representative. b Place a copy of the file in the iTX Media Watcher’s Inbox folder on your .lic network.
iTX Playout Appliance 2 Installation and Service Manual Configuring iTX (GVSP-3T-WIN-4IO/GVSP-3TB-WIN-8IO/GVSP-4TB- WIN-8IO) To integrate the iTX Playout Appliance 2 into an iTX system as a channel playout server, you must install and configure the required software modules, including Output Server 2. GVSP-3TB-WIN-4IO, GVSP-3TB-WIN-8IO and GVSP-4TB-WIN-8IO are not shipped with the iTX software modules already installed.
Servicing the iTX Playout Appliance 2 This chapter provides information about service procedures that can be performed on-site in cases where a faulty component must be replaced. WARNING All health and safety regulations and precautions must be observed as identified in Important Safeguards and Notices, on page iii.
Servicing the iTX Playout Appliance 2 Removing and Replacing the Bezel Removing and Replacing the Bezel The iTX Playout Appliance 2 has a front bezel which protects the drives and other front panel components from accidental removal or damage. The bezel can be completely removed from the unit to expose the unit’s front panel components.
iTX Playout Appliance 2 Installation and Service Manual Removing the Chassis Cover You can access the internal components of the iTX Playout Appliance 2 by removing the cover on the top side of the chassis. WARNING - Power Disconnection The system must be disconnected from all sources of power and the power cord removed from the power supply module(s) before accessing the chassis interior to install or remove system components.
Servicing the iTX Playout Appliance 2 Replacing a Hard Drive Replacing a Hard Drive The front panel provides access to ten drive carrier bays, which are populated by two SSD drives and four SATA hard drives; leaving four of the drive bays empty. The hard drives are hot swappable, meaning that you do not have to halt and shutdown the unit when replacing a single drive.
iTX Playout Appliance 2 Installation and Service Manual Replacing the Graphics Card WARNING - Power Disconnection The system must be disconnected from all sources of power and the power cord removed from the power supply module(s) before accessing the chassis interior to install or remove system components. This unit has more than one power supply connection.
Page 38
Servicing the iTX Playout Appliance 2 Replacing the Graphics Card 9 Remove the network adapter card from the bracket by carefully pulling it away from the middle of the bracket. 10 Remove the graphics card from the bracket by carefully pulling it away from the middle of the bracket.
iTX Playout Appliance 2 Installation and Service Manual Replacing the Network Adapter Card WARNING - Power Disconnection The system must be disconnected from all sources of power and the power cord removed from the power supply module(s) before accessing the chassis interior to install or remove system components. This unit has more than one power supply connection.
Servicing the iTX Playout Appliance 2 Replacing the SDI Video I/O Card (Corvid LP) 9 Remove the network adapter card from the bracket by carefully pulling it away from the middle of the bracket. 10 Replace the network graphics card by sliding the card into the bracket, ensuring that its connector is aligned and securely interfacing with the bracket’s middle connector.
Page 41
iTX Playout Appliance 2 Installation and Service Manual WARNING - Power Disconnection The system must be disconnected from all sources of power and the power cord removed from the power supply module(s) before accessing the chassis interior to install or remove system components. his unit has more than one power supply connection.
Page 42
Servicing the iTX Playout Appliance 2 Replacing the SDI Video I/O Card (Corvid LP) 7 Remove the screw(s) that secures the video card(s) to the bracket. 8 Remove the top video card from the bracket by carefully pulling it away from the middle of the bracket.
iTX Playout Appliance 2 Installation and Service Manual 12 Align the bracket with above its location within the chassis, ensuring that both cards’ connectors are align with the motherboard’s connectors. Press down on the bracket to ensure proper connection. 13 Lock the card bracket to the chassis by pressing down on the two small levers , or by fastening the four screws.
Page 44
Servicing the iTX Playout Appliance 2 Replacing the SDI Video I/O Card (Corvid 44 / 88) 8 Remove the screw that secures the video card to the bracket. 9 Remove the video card from the bracket by carefully pulling it away from the middle of the bracket.
Page 45
Contact Us Grass Valley Technical Support For technical assistance, contact our international support center, at 1-800-547-8949 (US and Canada) or +1 530 478 4148. To obtain a local phone number for the support center nearest you, please consult the Contact Us section of Grass Valley’s web site ( www.grassvalley.com An online form for e-mail contact is also available from the web site.