6-6 Power Supply Block Diagram

NOTE :
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
HOT CIRCUIT. BE CAREFUL.
F001
T1.6A L 250V
AC001
HOT
22
L003
D001 - D004
BRIDGE
LINE
RECTIFIER
FILTER
Q002
Q003
CAUTION
FOR CONTINUED PROTECTION AGAINST FIRE HAZARD,
REPLACE ONLY WITH THE SAME TYPE T1.6AL/250V FUSE.
VT-MX310E(UK)
T001
Q051
2
12
Q052
13
Q057
4
14
Q058
15
Q001
16
11
7
17
6
18
IC001
ERROR
VOLTAGE DET
4
1
3
2
REG
Q004
(SHUNT REGULATOR)
CAUTION !
Fixed voltage (or Auto voltage selectable ) power supply circuit is used in this unit.
If Main Fuse (F001) is blown, check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
MAIN CBA
VT-FX340E(UK)
Q053
Q055
Q054
Q059
VT-MX310E(UK)
Q056
COLD
P-ON+15V
P-ON+32V
P-ON-H
AL+12V/+20.5V
AL+9V
AL+12V
C-POW-SW
AL+5V
TIMER+5V
P-ON+5V
P-DOWN-L
P-OFF-H
AL-5V