Advertisement

Quick Links

SELF-CONTAINED UNIT
INSTALLATION & OPERATION INSTRUCTIONS
TO INSTALLER: Leave this manual with the Self-Contained Unit
TO CONSUMER: Keep this manual for future reference.
WARNING
Improper installation, adjustment, alteration, service, or maintenance can cause injury
or property damage. Read the installation, operating, and maintenance instructions
thoroughly before installing or servicing this equipment.
WARNING
Do not store or use gasoline or other flammable vapors and liquids in vicinity of this
or any other appliance. An LP-cylinder not connected for use shall not be stored in the
vicinity of this or any other appliance.
Read all instructions before you operate your Self-Contained Unit.
Save these instructions!
www.theoutdoorplus.com
V.042723.3

Advertisement

Table of Contents
loading

Summary of Contents for The Outdoor Plus SELF-CONTAINED UNIT

  • Page 1 SELF-CONTAINED UNIT INSTALLATION & OPERATION INSTRUCTIONS Read all instructions before you operate your Self-Contained Unit. Save these instructions! www.theoutdoorplus.com TO INSTALLER: Leave this manual with the Self-Contained Unit TO CONSUMER: Keep this manual for future reference. WARNING Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage.
  • Page 2 All fire pits must have a gas shut off on the outside of the exterior of the fire pit to allow for emergency shut off and maintenance. WARNING Product is not intended to be a starter for wood or any other combustibles. THE OUTDOOR PLUS | Self-Contained Unit Installation Manual...
  • Page 3 WARNING LABELS & SYMBOLS WARNING Select a location where the fire pit can be attended during operation. Never leave an operating fire pit unattended. WARNING Young children should be carefully supervised wehen they are in the area of the fire pit. WARNING Flammable gas under pressure.
  • Page 4 Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids. - The Outdoor Plus Company, Inc./TOPFIRES recommends that our products are installed by professionals locally licensed by the authority having jurisdiction in gas piping. All installation instructions must be followed to ensure proper performance and safety.
  • Page 5 WARNING LABELS & SYMBOLS DANGER FLAMMABLE GAS UNDER PRESSURE. LEAKING LP-GAS MAY CAUSE A FIRE OR EXPLOSION IF IGNITED CAUSING SERIOUS BODILY INJURYOR DEATH. CONTACT LP GAS SUPPLIER FOR REPAIRS, OR DISPOSAL OF THIS CYLINDER OR UNUSED LP-GAS. WARNING FOR OUTDOOR USE ONLY.* DO NOTUSE OR STORE CYLINDER IN A BUILDING, GARAGE OR ENCLOSED AREA.
  • Page 6 This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov. THE OUTDOOR PLUS | Self-Contained Unit Installation Manual...
  • Page 7: Site Preparation

    Before you begin assembling your fountain, you should carfully conside the following factors when selecting a location: 1. Ventilation: Some self-contained unit have both fire & water feature. If you unit have these both elements which require proper ventilation to prevent any harmful build-up of carbon monoxide or other gases. Always install the fountain in a well-ventilated area with plenty of fresh air flow.
  • Page 8: Gas Pressure

    - Certified CSA ANSI Z21.97-(2017) / CSA 2.41-(2017) certified. - The Pilot is designed to have robust flame pattern that is wind-resistant. - The coils are encapsulated to protest against moisture ensuring that the electrical componets remain safe and operational. THE OUTDOOR PLUS | Self-Contained Unit Installation Manual...
  • Page 9: Water Connection

    SITE PREPARATION | Water Connection WATER CONNECTION: Connecting the water system on the Fire & Water Fountain is an important step in the installation process. The fountain uses a water supply line to provide water to the fountain and it’s components. It is important to ensure that the water supply line is properly installed and connected to a shut-off valve that can be easily accessed in case of an emergency.
  • Page 10: Proper Location

    The fountain uses a gas-powdered burner system to produce flames, which produce heat and carbon dioxide. WARNING Improper venting of the Fire & Water Fountain can result in the buildup of harmful gases, which can be a serious safety hazard. THE OUTDOOR PLUS | Self-Contained Unit Installation Manual...
  • Page 11 ASSEMBLY | Fire Feature Installation ELECTRICAL REQUIR- BURNER MENTS: Pilot NOTE: The Electronic Box is can only be operated using 12 Volts. Gas Lead Coupling Orifice DO NOT attempt to power the Electronic Box using 110 Volts, it will damage the internal components. Electrical Lead RUNNING GAS LINE: Low Voltage Electronic Box...
  • Page 12 96” 96” 48” 48” Piolt Pilot Connections Electrical Leads Cross Ventilation on Opposite Side. Fire & Water Fountain already comes equipped with 360 degrees of ventilation. Control Panel Non-Combustible Flooring Electrical Leads THE OUTDOOR PLUS | Self-Contained Unit Installation Manual...
  • Page 13 WARRANTY REQUIRMENTS: Adequate drainage is essential to prevent damage to surrounding surfaces in your chosen location. Please note that The Outdoor Plus does not provide a warranty against drips or leaks and assumes no responsibility for any damages. As the installer, it is your responsibility to ensure that there is sufficient drainage to enable maintenance, repair, winterization, or potential leaks from the water basin.
  • Page 14 ASSEMBLY | Water Feature Installation Union Nut Pump Hose Auto-Fill Auto-Fill Hose House Water System 24/7 Water Pump Clean Water Filter System THE OUTDOOR PLUS | Self-Contained Unit Installation Manual...
  • Page 15 ASSEMBLY | Leveling Your Fire & Water Feature IMPORTANCE OF LEVELING: It is important to your Fire & Water Fountain. When the fountain is not level, it can affect the overall appearance and functionality of the fountain. A sloping fountain can cause water to overflow in on area, leading to an unbalanced appearance.
  • Page 16 Modifications or deviations from the wiring instructions provided in the manual could void the manufacturer’s warranty and create serious safety hazards. Always follow the wiring instructions carefully to ensure safe and proper operation of the fountain. THE OUTDOOR PLUS | Self-Contained Unit Installation Manual...
  • Page 17 This can be: Transformer, Dial Timer, E-Stop, AUTOMATION SYSTEM Bluetooth System. LOW VOLTAGE IGNITION SYSTEM Power Switch: Control Remote or Commercial Light Switch 110V Leads Low Voltage Leads 12 Volts...
  • Page 18: Start-Up & Testing

    PERFORM A GAS LEAK TEST: It is important to ensure that you conduct a gas leak test before starting your Fire Feature on your Self-Contained Unit. Here a step-by-step guide on how to conduct a gas leak test on your unit: Step 1: Turn off the Gas Supply The first step is to turn off the gas supply to the fire and water fountain.
  • Page 19 Fire Feature Unit. 3. Once the fire feature has been added, you can schedule the self-contained unit to turn on to a set schedule, when an event occurs, or you can manually turn each feature on.
  • Page 20 Do not allow the remote control to become wet or submerged in water. WARNING Make sure that the remote control is paired properly with the Bluetooth system and that both devices are functioning properly before use. THE OUTDOOR PLUS | Self-Contained Unit Installation Manual...
  • Page 21 START-UP & TESTING| Start-Up DIAL TIMER (Start-Up): Always follow the manufacturer’s instructions and safety guidelines when operating any kind of fire or water feature, and exercise caution when using a timer or other electronic device to activate it. If you have any concerns or issues with the operation of your fire &...
  • Page 22: Maintenance And Troubleshooting

    TAKING CARE OF YOUR SELF-CONTAINED UNIT: It is important to properly maintain your Self-Contained Unit clean to ensure it longevity and safe operation. By reg- ularly maintaining your unit it helps to prevent coslty repairs, but also ensure that your fountain is always looking it best.
  • Page 23 MAINTENANCE & TROUBLESHOOTING | Toubleshoot Guide PROBLEM POSSIBLE CAUSES SOLUTION 1. Not enough water. 1. Add more water 2. No Power 2. Ensure there is power running to the unit WATER IS NOT TURNING ON 3. Breaker Tripped 3. Reset breaker on electrical control box 4.
  • Page 24 HOUSING KIT LED LIGHT OPT-RP-WPMP OPT-AUTORF OPT-RP-FCRT OPT-RP-DRV OPT-RP-LEDHU OPT-RP-LEDLF LED MODULE TRANSFORMER UNION NUT OPT-RP-LEDMD OPT-RP-LED12V OPT-RP-UNT FIRE FEATURE REPLACEMENT PARTS: LOW VOLTAGE PILOT ELECTRICAL LEADS KIT COMPLETE KIT OPT-500PI OPT-PIEXT TOP-500EIS-100-12 THE OUTDOOR PLUS | Self-Contained Unit Installation Manual...
  • Page 25: Warranty And Support

    Customer Support Contact Information At The Outdoor Plus, we are commited to providing excellent custromer service to all of our customers. If you need assistance in ordering parts for your Fire & Water Fountain, please contact our sales team at: sales@theoutdoorplus.com Our knowledgeable sales team can assist you in identifying the correct parts and...
  • Page 26 If you suspect that a unit or component you received is - Warranty starts from the original sale/shipment date defective, you can send it to The Outdoor Plus for testing from The Outdoor Plus. at their facility. The Outdoor Plus will cover the shipping costs for sending the component back to you.
  • Page 27 CONGRADULATIONS! We wanted to take a moment to extend our sincere gratitude for choosing The Outdoor Plus for your recent Fire & Water Fountain purchase. We hope that it will provide many years of enjoyment. Our team takes great pride in crafting each unit with the utmost attention to detail and precision, and we are delighted to hear that you appreciate the hard work and craftsmanship that has gone into making your fountain.
  • Page 28 THE OUTDOOR PLUS 701 S DUPONT AVE ONTARIO, CA 91761 Contact Information: Phone: (909) 460 5579 Sales: sales@theoutdoorplus.com Support: support@theoutdoorplus.com...

Table of Contents