Troubleshooting (cont.)
(Optional) Chromatherapy Troubleshooting Table
Symptom
1.
Chromatherapy lights do
not work.
2.
The Chromatherapy lights
do not cycle through all
colors.
3.
The Chromatherapy lights
remain locked on one
color when cycled.
1181168-5-A
Probable Cause
A. Power to the control amplifier is
off.
B. The control amplifier must be
reset.
C. The control amplifier does not
work.
D. The Chromatherapy or user
interface cable connections are
loose or damaged.
E. The user interface does not
work.
The Chromatherapy feature has
F.
not been selected on the user
interface.
G. The Chromatherapy control
does not work.
A. The control amplifier must be
reset.
B. The control amplifier does not
work.
C. The Chromatherapy or user
interface cable connections are
loose or damaged.
D. The user interface does not
work.
E. If none of the recommended
actions correct the problem,
contact Kohler Co.
A. The control amplifier must be
reset.
B. The control amplifier does not
work.
14
Recommended Action
A. Reset the circuit breaker to the
control amplifier, then check the
electrical power supply and
connections.
B. If the red LED on the control
amplifier is not blinking, unplug
the control amplifier for 30
seconds, then plug in and restart.
C. If the red LED on the control
amplifier is still not blinking
following restart, replace the
control amplifier.
D. Inspect the cables for loose
connections or damage. Tighten or
replace the cables as needed.
E. Verify that the user interface cable
is securely connected to the user
interface and the control amplifier
terminal. If the connections are
good, replace the user interface.
Select the Chromatherapy feature
F.
on the user interface.
G. Replace the Chromatherapy
control.
A. If the red LED on the control
amplifier is not blinking, unplug
the control amplifier for 30
seconds, then plug in and restart.
B. If the red LED on the control
amplifier is still not blinking
following restart, replace the
control amplifier.
C. Inspect the cables for loose
connections or damage. Tighten or
replace the cables as needed.
D. Cycle through the Chromatherapy
light functions. If the
Chromatherapy lights do not cycle
through all colors and the blue icon
on the user interface is not lit,
replace the user interface.
E. Contact the Customer Care Center
using the contact information on
the back cover.
A. If the red LED on the control
amplifier is not blinking, unplug
the control amplifier for 30
seconds, then plug in and restart.
B. If the red LED on the control
amplifier is still not blinking
following restart, replace the
control amplifier.