N-BIOTEK NB-203 Operation Manual

N-BIOTEK NB-203 Operation Manual

Co2 incubator

Advertisement

Quick Links

CO
Incubator Operation Manual
2
Model: NB-203 / NB-203XL
1

Advertisement

Table of Contents
loading

Summary of Contents for N-BIOTEK NB-203

  • Page 1 Incubator Operation Manual Model: NB-203 / NB-203XL...
  • Page 2: Table Of Contents

    CONTENTS Page 1. SAFETY AND GENERAL PRECAUTION 3 ~ 5 2. TRANSPORTATION, STORAGE AND LOCATION OF INSTALLATION 5 ~ 6 3. PREREQUISITE AND CONFIGURATION 7 ~ 8 4. FEATURES AND SPECIFICATIONS OF THE UNIT 5. CONTROL PANEL 6. OPERATION 11 ~ 14 7.
  • Page 3: Safety And General Precaution

    1. SAFETY AND GENERAL PRECAUTION 1.1 General Information on Precaution Precaution is to prevent the possible accident or danger during operation. ⚫ So, you must keep it. Pprecaution is divided into caution and warning. And, each of them has following meanings. ⚫...
  • Page 4 When you see smoke coming from the product or smell something is burning or see any other strange symptoms, you have to pull out the power cord and stop using it. (It can cause an electric shock and a fire.) 1.3 Precaution for ground connection Please ground before use the product, if you don't ground, you can get an electrocution when malfunction or an electric leakage occurs.
  • Page 5: Transportation, Storage And Location Of Installation

    Do not wash the product with excessive quantity of water, thinner, benzene and Petroleum. (It can cause an electric leakage, and malfunction or damage on the surface.) When you don't use the product or clean it, please pull out the power plug. (It is to prevent an eclectic leakage.) Open and close the door softly and please use a door knob.
  • Page 6 Do not install at a humid place. (It causes an electric leakage accident and a corrosive of the product.) Keep this product out of the direct ray of sun and do not install at a hot place or a place that is near an electric heat. (The proper indoor temperature is 20℃...
  • Page 7: Prerequisite And Configuration

    3. PREREQUISITE AND CONFIGURATION 3.1 PREREQUISITE Inspection of Boxes When you have received the instrument, which is packed on pallet, inspect the box carefully for any damages that may have caused any damages to product during shipping. Please report any damage to the carrier or to your local NBIOTEK distributor immediately. LOCATION The incubator is designed to operate at temperature 5℃...
  • Page 8 3.2 CONFIGURATION Exterior Configuration of CO2 incubator. <Figure #1> Control panel Air jacket -6 side direct heating Power switch Circulation fan Magnetic door seal Glass door heater -Prevent condensation Glass door Stainless steel shelves - Perforated to improve uniformity Door latch Inner door seal - Airtight to prevent CO leakage...
  • Page 9: Features And Specifications Of The Unit

    4. FEATURES AND SPECIFICATIONS OF THE UNIT 4.1 Features 1. Excellent Uniformity of Temperature, CO (optional) 2. 6 Side Direct Heat for Temperature Uniformity and Fast Recovery 3. IR CO₂Sensor detects precise density of CO₂ 4. Outer Heated Door ensures no condensation on glass door. 5.
  • Page 10: Control Panel

    5. CONTROL PANEL 1. Temp Safety Indicator : Lighting, in case of Thermal cut-off is activated by over temperature 2. Alarm Mute : For Temporary Pause when Sound of Alarm is activated 3. Heating Activation Indicator : If part of heater is heated, lamp is flashing 4.
  • Page 11: Operation 11

    6. OPERATION Before Switch ON, insert water tray filling with distilled water. Make sure connection of gas supply. And Open CO₂ gas cylinder or supply with the pressure of regulator in 14.5Psi or 1 bar. 1) Turn on the power switch The digital readout of current temperature and density of CO2 &...
  • Page 12 6.2 CALIBRATAION OF TEMPERATURE & CO₂: Please follow up below procedure for calibration in case of discrepancy between actual value (measured by reliable measurement device) in chamber and displayed value. Measure CO₂ density and Temperature after incubator is stabilized in which takes about more than 2 hours (you might want to perform this stabilization process at night before home) Please note that low deviation range such as ±0.1 ~ 0.3% may not be corrected precisely by this calibration.
  • Page 13 b. Second Click “CAL/SET” ☞ Outer door’s Temp calibration Channel 2 is purposed to remove water condensing on glass door caused by high temperature difference between chamber and outside. Recommend to use calibration at Channel 2 in case of water condensing on glass door. Note Except water condensing on glass door, calibration of channel 2 and 3 is not recommendable.
  • Page 14 NOTE Channel 5 is to set heating control point. If it is set at 3, then the heating control works from 34’C against setting value i.e. 37’C. This is in order to minimize overshooting and faster reaching time to setting value. Therefore, user is kindly required not to change this value.
  • Page 15: Overheating Safety

    If the alarm was stopped by mute button, the audible alarm(except alarm for the door) will be re-activated every 10minutes from the initial alarm if either or both CO2 and Temperature is still in alarm range. This is to remind user of the error which continued and not corrected. 7.
  • Page 16: Trouble Shooting

    Replace SSR relay Power not supplied to heating Reconnect the power plug on circuit the panel. Contact N-BIOTEK service Unit does not switch on The miniature fuse has blown. Replace the fuse with type (main switch is in position “l”...
  • Page 17: Warranty

    N-BIOTEK, whichever is sooner as indicated in above table. This period is proved by serial number. 3. N-BIOTEK will not be responsible of free warranty service for the faulty caused by user’s improper operation, excessive use, use of incorrect voltage & frequency, storage in wrong environment mentioned in Manual.

This manual is also suitable for:

Nb-203xl

Table of Contents