Boat Assembling; Valves Operation - GALA C Series User Manual

Table of Contents

Advertisement

BOAT ASSEMBLING

4.
-
Inspect the condition of the package for and report to your
Step 1:
dealer if you find any damages.
Open the
- Remove all the packaging plastic and cardboard carefully. Do
boat
not use knife.
- Check the completeness of the boat and make sure that no
any parts are missing. You must report the missing part to your
dealer immediately.
Step 2:
- Open the pump, connect the pump hose to the pump onto
low pressure inflation opening.
Inflate the
- Connect bayonet adapter of the pump hose to the valve
boat
- Inflate the tube rear compartments first up to pressure
slightly below nominal, and the bow compartment the last
up to the nominal pressure (0.2 bar/ 3 psi). In this case the
flexible baffles in the tube will move towards the rear
compartments and equalize the pressure in all compartments.
You may use the manometer to measure the pressure level to
ensure the best performance of the boat and make sure that
the pressure is about nominal level. Nominal tube pressure is
mentioned on Capacity Plate.
- switch the mode of your foot pump to high pressure mode
and inflate the air deck up to nominal pressure (0.6 bar/ 9 psi)
Step 3:
Unpack the seats and install them. For that slide the side seat
railings into the seat slots on both sides. Always keep the
Install the
seats at a distance not less than 100mm (4 inches) from the
seats
seat rail ends.
Install the motor following your motor User's Manual
Step 4:
instructions.
Install the
motor
- 4 -

VALVES OPERATION

5.
a)
INFLATION-DEFLATION VALVE operation:
b)
DRAIN VALVE operation:
OVERINFLATING AND OVERHEATING OF YOUR BOAT MAY CAUSE THE
BOAT DAMAGE. AVOID OVERPUMPING THE BOAT, LEAVING THE BOAT
NOT COVERED, USING HIGH-PRESSURE INFLATORS. USE MANOMETER TO
CHECK THE PRESSURE IN THE TUBE REGULARLY.
WARNING
- 5 -
Inflation-deflation valve has PUSH-
PUSH operating system: pressing
the central pin the valve switches
between OPEN and CLOSED. To
inflate the tube put the pin to
CLOSED position (pin moves UP).
To deflate the tube put the pin to
OPEN position (pin moves DOWN).
After inflation every valve must be
closed with the valve plug tight to
ensure airtightness of the tube.
Drain valve includes:
a) Lifting OPEN-CLOSE lever: in
upper position the valve is OPEN
and water can get out of the cockpit,
in
lower
position
the
valve is
CLOSED and water passage is
blocked
b) one-way drain valve with petal
prevent the water coming into the
cockpit.
Close your valve when driving, and
open your valve to drain the boat if
you discover any water collection in
the cockpit.
.

Advertisement