Samsung DW80R5061 Series Service Manual page 50

Hide thumbs Also See for DW80R5061 Series:
Table of Contents

Advertisement

Check Type
Check Mode
High
Temperature
HC
Heating Check
Leakage Check
LC
Temperature
tC
48 _ Troubleshooting
Checking Method
1. Check the hot water connections for the Inlet Valve.
2. Check the operation of the Thermistor.
Check whether there is any trace of water leakage in the shutter.
- Measure the voltage between both ends of the Thermistor
Remove the connector before measuring.
- Measure the voltage between number 2 and 4 in the connector with power.
Temp.
Temp.
41
10
98.323
20
68
77
49.12
30
86
31.996
40
104
113
122
131
60
140
12.14
149
70
Resistance
133.219
1.026
103.638
1.203
81.249
1.393
61.477
1.804
2.018
2.234
2.447
21.347
3.048
12.136
3.228
3.396
Corrective actions