X2-CB-C BUOY-MOUNTED DATA LOGGER
QUICK START GUIDE
IMPORTANT - BEFORE FIELD DEPLOYMENT: Completely configure new X2 systems with sensors and a web connec-
tion in a nearby work area. Operate the system for several hours and ensure correct sensor readings. Use this test run
to become familiar with the features and functions.
Figure 1: X2-CB Buoy-Mounted Data Logger

Overview

The X2-CB buoy-mounted data logger with cellular te-
lemetry includes an integrated modem. Five sensor ports
provide industry standard protocols including SDI-12, RS-
232, and RS-485. The Solar/COM port offers direct com-
munication (serial to PC) and power input. The X2-CB is
powered from the CB-Series buoy's solar rechargeable
battery reserve.
Data is accessed and stored on the WQData LIVE web
datacenter. An easy-to-use dashboard and built-in sensor
library automatically facilitate setup and configuration.
What's Included?
(1) X2-CB buoy-mounted data logger
(5) Sensor port plugs, (3) spare orings
(1) Power port plug, (2) spare orings
(1) Oring grease
(2) Spare sensor port plugs
(1) Wireless antenna (installed on telemetry units only)
(1) Quick start guide

To get started:

1
a.
Go to
WQDataLIVE.com
b.
Create a new account or sign into an existing
account.
c.
Choose or create the project that will contain
the data logger by selecting the Projects link
from the bottom right footer of the page.
d.
Go to the ADMIN tab located at the top of the
project dashboard and click Settings.
From there, choose the Project/Site pull down
2
menu and select the site for the new data logger.
a.
If a site has not been created, select New Site.
Create and save the site before entering the
claim code.
Enter the claim code listed below into the space
3
provided under Assigned Devices.
Click Add Device.
4
a.
The new device should be visible in the
Assigned Devices list.
If cellular service is not purchased through
5
NexSens, visit the article link below for steps on
how to setup the cell modem.
a.
nexsens.com/x2apn
Use the CONNECT software to ensure the proper
6
scripts are enabled for each sensor.
a.
nexsens.com/conncss
Remove one blank sensor plug from an 8-pin port
7
(i.e., P0, P1, or P2) for each sensor.
a.
Connect all sensors to the desired ports.
Note: Only one RS-232 sensor can be plugged into
each P0, P1, or P2 port, (i.e., either P0-A or P0-B.).
Ensure that all SDI-12 and RS-485 sensors have
unique addresses.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the X2-CB-C and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for NexSens Technology X2-CB-C

  • Page 1 X2-CB-C BUOY-MOUNTED DATA LOGGER QUICK START GUIDE IMPORTANT - BEFORE FIELD DEPLOYMENT: Completely configure new X2 systems with sensors and a web connec- tion in a nearby work area. Operate the system for several hours and ensure correct sensor readings. Use this test run to become familiar with the features and functions.
  • Page 2 Buzzer Pattern Indicators Remove the SOLAR/COM blank plug from the 6-pin port. Connect the 6-pin solar panel plug to power Table 1: X2-CB Buzzer Pattern Indicators. the X2-CB. The device will beep once when powered. Beep Type Status Buzzer Event When power is One short System boot...

Table of Contents