Beijer Electronics SER0060 Quick Start Manual

X2 to bfi e3 modbus tcp – ix script module

Advertisement

Quick Links

Quick start guide
X2 to BFI E3 Modbus TCP – iX script module
SER0060 – X2 ModBusTCP to BFI E3-MTP example

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SER0060 and is the answer not in the manual?

Questions and answers

Summary of Contents for Beijer Electronics SER0060

  • Page 1 Quick start guide X2 to BFI E3 Modbus TCP – iX script module SER0060 – X2 ModBusTCP to BFI E3-MTP example...
  • Page 2: Function And Area Of Use

    Copyright © Beijer Electronics, 2022 This documentation (below referred to as ‘the material’) is the property of Beijer Electronics. The holder or user has a non-exclusive right to use the material. The holder is not allowed to distribute the material to anyone outside his/her organization except in cases where the material is part of a system that is supplied by the holder to his/her customer.
  • Page 3: Table Of Contents

    6 The iX Project ...................... 9 Main Menu ....................9 All Parameters Menu ..................10 Remote IO Menu ..................10 Other Screens ..................... 11 7 Import the project parts ..................12 8 About Beijer Electronics ..................13 Contact us ....................13 3 (13)
  • Page 4: Preparing The Communication

    X2 to BFI E3 Modbus TCP – iX script module SER0060_V1.0.0 2022-02 4 Preparing the Communication This section describes the settings both for the BFI and the iX ModBus Master controller and some other helpful information. BFI parameter settings BFI-E3: - P12=3.
  • Page 5: Indication Of Status On Led Of Bfi-E3

    X2 to BFI E3 Modbus TCP – iX script module SER0060_V1.0.0 2022-02 Indication of status on LED of BFI-E3 Example of LED indication of ethernet ports in BFI-E3. Communication working Communication interruption Network Status Indicator, NS State Indication Steady Off BFI is not powered up or no IP address Flashing Green Online, no Modbus TCP connections active...
  • Page 6: Web Server In Bfi-E3

    X2 to BFI E3 Modbus TCP – iX script module SER0060_V1.0.0 2022-02 5 Web server in BFI-E3 Default IP-address of BFI-E3 is 192.168.1.253 and Subnet: 255.255.255.0 Enter IP-address in the web browser. Username is Admin and Password is the serial number of the BFI. Module Configuration •...
  • Page 7: Network Statistic

    X2 to BFI E3 Modbus TCP – iX script module SER0060_V1.0.0 2022-02 Network Statistic • 192.168.1.29 is the IP-address of the PC. Local port 80 with Socket type TCP is the web browser connection with BFI. • 192.168.1.29 is the IP-address of the PC. Local port 47850 with Socket type TCP is PC-program BFI- Tools running on the PC.
  • Page 8: How To Change Ip-Address And Network Mask

    X2 to BFI E3 Modbus TCP – iX script module SER0060_V1.0.0 2022-02 How to change IP-address and Network mask • Enter new IP-address and/or Network Mask • Push on Apply New Values iX ModBusTCP settings Configure the controller settings as shown below. 8 (13)
  • Page 9: Modbusrtu And Modbustcp Parallely

    X2 to BFI E3 Modbus TCP – iX script module SER0060_V1.0.0 2022-02 ModBusRTU and ModBusTCP parallely It is not possible to run ModBus RTU and ModBus TCP at the same time! 6 The iX Project The most important screens of the iX are the Main menu (Demo_Main) and the All Parameters menu (Demo_AllPar).
  • Page 10: All Parameters Menu

    X2 to BFI E3 Modbus TCP – iX script module SER0060_V1.0.0 2022-02 All Parameters Menu On this screen you can read and write the BFI parameters. Remote IO Menu On this screen you can see the sate of the digital and analog Inputs. 10 (13)
  • Page 11: Other Screens

    X2 to BFI E3 Modbus TCP – iX script module SER0060_V1.0.0 2022-02 Other Screens General BFI information. Trend based on a DataLogger. Additionally there are a Help screen and a System Information screen. This example works well for X2 baseV2/pro/marine/control/extreme series devices. Please follow below guidelines how to install into your application.
  • Page 12: Import The Project Parts

    X2 to BFI E3 Modbus TCP – iX script module SER0060_V1.0.0 2022-02 7 Import the project parts Follow the steps to add the enclosed screenS and the script module to your iX project: 1. Unpack the enclosed example ZIP-file to a temporary folder.
  • Page 13: About Beijer Electronics

    As experts in user-friendly software, hardware and services for the Industrial Internet of Things, we empower you to meet your challenges through leading-edge solutions. Beijer Electronics is a Beijer Group company. Since its start-up in 1981, BEIJER GROUP has evolved into a multinational group with sales of 1.4 billion SEK 2020.

Table of Contents