VDH ALFA 31 DP User Manual

VDH ALFA 31 DP User Manual

Cool/heat thermostat

Advertisement

Quick Links

VDH doc. 970629
Software ALFA 31DP

* Installation.

On the Topside of the ALFA 31 DP you can see how the sensor, power supply and relay have to
be connected.
After connecting the ALFA 31 DP to the power supply, a self test function is started. As this test is
finished the measured temperature appears in the display.
When the relay is activated, the led 'on' will light in the display.

* Control.

The ALFA 31 DP thermostat can be controlled by three pushbuttons on the front. These keys are:
SET
- view / change the setpoint.
UP
- increase the setpoint.
DOWN
- decrease the setpoint.

* Viewing setpoint.

By pushing the SET key the setpoint appears in the display. The led 'set' starts blinking. A few
seconds after releasing the SET key the setpoint disappears and the measured temperature is shown
in the display.

* Changing setpoint.

Push the SET key and the setpoint appears in the display. Release the SET key. Now push the SET
key again and together with the UP or DOWN keys the setpoint can be changed.
A few seconds after releasing the keys the measured temperature is shown again in the display.
User manual ALFA 31 DP
Cool/Heat Thermostat.
Version: v1.1
File: DO970629.WP8
Range: -10,0/+40,0 °C per 0,1°C
1
Date: 02-11-1999

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ALFA 31 DP and is the answer not in the manual?

Questions and answers

Summary of Contents for VDH ALFA 31 DP

  • Page 1 Range: -10,0/+40,0 °C per 0,1°C * Installation. On the Topside of the ALFA 31 DP you can see how the sensor, power supply and relay have to be connected. After connecting the ALFA 31 DP to the power supply, a self test function is started. As this test is finished the measured temperature appears in the display.
  • Page 2 20 seconds no key is pushed, the ALFA 31 DP changes to its normal operation mode. * Adjustment sensor. The sensor can be adjusted by using the Sensor Offset (parameter 04). Indicates the ALFA 31 DP e.g. 2°C too much, the Sensor Offset has to de decreased by 2°C.
  • Page 3 * Parameter ALFA 31 DP. PARA- DESCRIPTION PARAMETER RANGE DEFAULT METER VALUE Switching differential 0,1..10°C Minimum setpoint -10..+40°C -10.0 Maximum setpoint -10..+40°C +40.0 Offset temperature sensor -10..+10°C Startup delay after power 0..99 Min. failure Relay on at sensor failure 0 = No...
  • Page 4 * Dimensions * Connections * Function diagram...