* Description.

The ALFANET 95 is a cooling/heating thermostat with various automatic defrost and fan drive facilities.
It can be programmed through the ALFANET PC-INTERFACE on the PC.

* Installation.

On the connection diagram of the ALFANET 95 is shown how the sensor, power supply and relays
should be connected. After the ALFANET 95 has been connected to the power supply a self-test
function will take place, after which the measured temperature will appear in the display.

* Operation.

The ALFANET 95 thermostat can be operated by means of four pushbuttons on the front. These
pushbuttons are:
SET
- view / change the set point.
UP
- raise the set point.
DOWN
- lower the set point.
 C
- hidden key under the  C text.

* Normal operation status.

During normal operation the temperature of the control sensor is shown in the display.

* Viewing the set point.

By pressing the SET key the set point becomes visible. At the same time the decimal point of the right-
hand display will blink, as an indication that the set point is being read. A few seconds after the SET
key has been released, the set point will disappear and the measured value will be visible again.
Version: v1.1
File: Do080643.wpd
1
Date: 12-04-2011
Range: -50,0/+50,0  C

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Alfanet 95 and is the answer not in the manual?

Questions and answers

Summary of Contents for VDH Alfanet 95

  • Page 1 It can be programmed through the ALFANET PC-INTERFACE on the PC. * Installation. On the connection diagram of the ALFANET 95 is shown how the sensor, power supply and relays should be connected. After the ALFANET 95 has been connected to the power supply a self-test function will take place, after which the measured temperature will appear in the display.
  • Page 2: Error Messages

    11). For reading the temperatures of the defrost sensor choose parameters 07 and 10. Should a sensor of the ALFANET 95 indicates 2  C too much, for example. Then the according Sensor Offset must be lowered by 2  C.
  • Page 3 SET key. If, after pressing the SET key (=reset alarm) the alarm is not yet solved, then the ALFANET 95 shows the temperature and error code alternately, if the alarm has been solved then the error code disappears and the temperature is shown again.
  • Page 4 * Parameters ALFANET 95. Para- Description of Parameter Range Standard meter value Switching differential 0,1..15,0°C Minimum adjustable set point -50..+50°C Maximum adjustable set point -50..+50°C Readout above -10  C in whole degrees 0 = No, 1 = Yes Offset control sensor -15,0..+15,°C...
  • Page 5: Technical Data

    Production week 1..52 Series number (x1000) 0..255 Series number (units) 0..999 * Technical data. Type : ALFANET 95 Cool/Defrosting Thermostat CONTROL-UNIT: : -50,0/+50,0  C Range Read-out : 3-digit 7-segments display Accuracy : ± 0,5 % of the range. : ALARM, COMPR., FAN, DEFR.1 and DEFR.2 (On display through  C key)
  • Page 6 * Dimensions of ALFANET 95. Control-unit I/O-unit...
  • Page 7 * Connection data. Diagram: 042527w2...
  • Page 8 * Function diagram. * Address VDH Products BV Tel: +31 (0)50 - 30 28 900 Produktieweg 1 Fax: +31 (0)50 - 30 28 980 9301 ZS Roden Email: info@vdhproducts.nl Netherlands Internet: www.vdhproducts.nl...

Table of Contents