VB0+ VB1- VB1+ 22~27 High voltage LCD Power Supply VLCD Bus mode;The interface bus mode is determined by BM[1:0]: Mode BM[1;0] 8080(8-bit) 6800(8-bit) 4-wire SPI w/ 8-bit token (S8) 2-wire SPI(I²C) URL: www.topwaydisplay.com Document Name: LM6020FCW-2-Manual-Rev0.1.DOC Page: 4 of 14...
TYP. MAX. Unit Applicable Pin Forward Voltage Forward Current Cautions: Exceeding the recommended driving current could cause substantial damage to the backlight and shorten its lifetime. No. of LED = 2pcs URL: www.topwaydisplay.com Document Name: LM6020FCW-2-Manual-Rev0.1.DOC Page: 5 of 14...
Chip select hold time tcsh80 Note: *1. Input signal rise/fall time should be less than 15ns . *2. CL=100pF *3.All timing is using 20% and 80% of VDD as the reference. URL: www.topwaydisplay.com Document Name: LM6020FCW-2-Manual-Rev0.1.DOC Page: 6 of 14...
Page 7
READ Output disable time tOD68 Note: *1. Input signal rise/fall time should be less than 15ns . *2. CL=100pF *3.All timing is using 20% and 80% of VDD as the reference. URL: www.topwaydisplay.com Document Name: LM6020FCW-2-Manual-Rev0.1.DOC Page: 7 of 14...
Page 8
Chip select hold time tCSHs8 Note: *1. Input signal rise/fall time should be less than 15ns . *2. CL=100pF *3.All timing is using 20% and 80% of VDD as the reference. URL: www.topwaydisplay.com Document Name: LM6020FCW-2-Manual-Rev0.1.DOC Page: 8 of 14...
Page 9
=0V, V =3.3V, T =25C Item Symbol MIN. TYP. MAX. Unit Reset time μs Reset LOW pulse width Note: *1.All timing is using 20% and 80% of VDD as the reference. URL: www.topwaydisplay.com Document Name: LM6020FCW-2-Manual-Rev0.1.DOC Page: 9 of 14...
The LCD module should be initialized by using /RES terminal. While turning on the VDD and VSS power supply, maintain /RES terminal at LOW level. After the power supply stabilized, release the reset terminal (/RES=HIGH) URL: www.topwaydisplay.com Document Name: LM6020FCW-2-Manual-Rev0.1.DOC Page: 10 of 14...
TOPWAY LCD Module User Manual LM6020FCW-2 4.6 Display Commands The following is a list of host commands supported by UC1628c: URL: www.topwaydisplay.com Document Name: LM6020FCW-2-Manual-Rev0.1.DOC Page: 12 of 14...
Page 13
It recommends that enter Sleep Mode before power off the LCD module. 4.6.2 Refreshing The LCD Module It recommends that the operating modes and display contents be refreshed periodically to prevent the effect of unexpected noise. URL: www.topwaydisplay.com Document Name: LM6020FCW-2-Manual-Rev0.1.DOC Page: 13 of 14...
LCD module reliability may be reduced by temperature shock. When storing the LCD module, avoid exposure to the direct sunlight, high humidity, high temperature or low temperature. They may damage or degrade the LCD module URL: www.topwaydisplay.com Document Name: LM6020FCW-2-Manual-Rev0.1.DOC Page: 14 of 14...