216, 216-L, 216-N
Active Infrared "Touchless" Switch
Section 1

General Description

The 216 Series "touchless" switches are active infrared
devices designed for hands-free activation of automatic
door operators or other access control products. The 216
switch assembly will fit in a variety of locations from a
1 3/4" door frame to a single or 2-gang or junction
electrical box. Various size surface mounting boxes are
also available from the factory. Three standard face plate
sizes are available:
216:
4 1/2" x 4 1/2" stainless steel (fits single, 2-
gang, junction electrical boxes)
216-L: 2 3/4" x 4 1/2" stainless steel (fits single gang
electrical boxes)
216-N: 1 11/16" x 4 1/2" stainless steel (fits 1 3/4"
door frames)
Section 2

Basic Installation

SINGLE GANG ELECTRICAL BOX: 216 & 216-L
1) Install the electrical box (purchased separately) in its
intended location.
2) Set the unit for its intended operating mode via the
jumpers on the side of the switch assembly: Fail
Close (factory setting), Fail Open or Toggle (Figure 1).
3) Make the appropriate electrical connections to the
switch assembly--4 wires are required (Figure 2).
4) Attach the switch assembly to the electrical box with
the two (2) 6-32 x 1/2" screws provided.
5) Adjust for range and time delay via the potentiometers
on the front of the switch assembly (Figure 3).
6) Attach face plate with the 6-32 x 3/8" screws provided
ensuring that the backside of the face plate lens and
the foam gasket on the front of the switch assembly
are less than 1/4" apart (Figure 4).
2-GANG ELECTRICAL BOX OR JUNCTION BOX: 216
1) Install the electrical box (purchased separately) in its
intended location.
2) Attach the adaptor ring provided (see below) to the
electrical box.
3) Set the unit for its intended operating mode via the
jumpers on the side of the switch assembly: Fail
Telephone: (800) 842-2545/(317) 842-2545
4) Make the appropriate electrical connections to the
5) Attach the switch assembly to the adaptor ring
6) Adjust for range and time delay via the potentiometers
7) Attach face plate with the 6-32 x 3/8" screws provided
DOOR FRAME: 216-N
1) Make a cutout in the door frame at the intended
2) Set the unit for its intended operating mode via the
3) Make the appropriate electrical connections to the
4) Mount the switch assembly in the cutout and attach
5) Adjust for range and time delay via the potentiometers
6) Attach face plate with the 6-32 x 3/8" screws provided
8701 Castle Park Drive
Indianapolis, Indiana 46256
www.mssedco.com
INSTALLATION INSTRUCTIONS
Close (factory setting), Fail Open or Toggle (Figure 1).
switch assembly--4 wires are required (Figure 2).
(mounted to the electrical box in step 2) with the 6-32
x 1/2" screws provided.
on the front of the switch assembly (Figure 3).
ensuring that the backside of the face plate lens and
the foam gasket on the front of the switch assembly
are less than 1/4" apart (Figure 4).
location. Drill and tap 2 mounting holes (see below).
DRILL & TAP
6-32 (2 Holes)
11/16"
3 1/4"
jumpers on the side of the switch assembly: Fail
Close (factory setting), Fail Open or Toggle (Figure 1).
switch assembly--4 wires are required (Figure 2).
with the 6-32 x 1/2" screws provided.
on the front of the switch assembly (Figure 3).
ensuring that the backside of the face plate lens and
the foam gasket on the front of the switch assembly
are less than 1/4" apart (Figure 4).
custsvc@mssedco.com
1 3/8"
2 7/8"
Page 1
(82A023) 216v0804

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 216 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MS Sedco 216

  • Page 1 4 1/2" x 4 1/2" stainless steel (fits single, 2- are less than 1/4" apart (Figure 4). gang, junction electrical boxes) 216-L: 2 3/4" x 4 1/2" stainless steel (fits single gang DOOR FRAME: 216-N electrical boxes) 1) Make a cutout in the door frame at the intended 216-N: 1 11/16"...
  • Page 2 Warranty MS SEDCO guarantees this product to be free from manufacturing defects for 1 year from date of installation. Unless MS SEDCO is notified of the date of installation, the warranty will be in effect for 1 year from the date of shipment from our factory. If, during the...
  • Page 3 1) Standard "Fail Close" Mode (Factory Setting): This is the most common operating mode. In this mode, if power were to fail to the 216 series switch, the door it is activating will stay closed (the switch relay is in its inactive state). The unit is shipped from the factory in this mode - no change to the jumpers is necessary.
  • Page 4 216, 216-L, 216-N Active Infrared "Touchless" Switch INSTALLATION INSTRUCTIONS FIGURE 3—Adjustments Diagram Range Adjustment: Clockwise to increase 6" to 30". RANGE NOTE: When attaching the face plate, the 6" to 30" range may increase. ACTIVATION INDICATOR Delay Hold Time Adjustment: Clockwise to increase 0 to 5 seconds.

This manual is also suitable for:

216-l216-n

Table of Contents