10. Allow generator to run at no load for few
minutes upon each initial start-up to permit
engine and generator to stablize.

Connecting Electrical Loads

This unit has been pretested and adjusted to
handle its full capacity. Before starting the
generator, disconnect all load. Apply load only
after generator is running. Voltage is regulated
via the engine speed adjusted at the factory for
correct output. Readjusting will void warranty.
CAUTION
When applying a load, do not exceed the maximum
wattage rating of the generator when using one or
more receptacles. Also, do not exceed the amperage
rating of any one receptacle.
Do not apply heavy electrical load during break-in
period (the first five hours of operations).
1.Let engine stabilize and warm up for a few
minutes after starting.
2.Ensure circuit breaker on control panel is in
on position.
3.Plug in and turn on the desired 120 Volt
AC, single phase, 60Hz electrical loads. It is
better to attach the item with largest load first.
Connecting a generator to your electric utility
company's power lines or to another power source
may be against the law. In addition this action, if
done incorrectly, could damage your generator
and appliances and could cause serious injury or
even death to you or a utility worker who may be
English
working on nearby power lines. If you plan to run
a portable electric generator during an outage,
please notify your electric utility company
immediately and remember to plug your appliances
directly into the generator. Do not plug the
generator into any electric outlet in your home.
Doing so could create a connection to the utility
company power lines. You are responsible for
ensuring that your generator's electricity does not
feed back into the electric utility power lines. If the
generator will be connected to a building electrical
system, consult your local utility company or a
qualified electrician. Connections must isolate
generator power from utility power and must
comply with all applicable laws and codes.

Stopping the Engine

1. Turn off and remove entire electrical loads.
Never start or stop the generator with
electrical devices plugged in or turned on.
Let the generator run at no-load for two
minutes to stabilize internal temperatures
of the engine and generator.
2. Turn the fuel selector switch to OFF (O)position.
GAS
3. Fully close the LPG cylinder knob.
Page 24