  • Page 1 Articulating Legs with Intraosseous Infusion Simulator LF03840U Instruction Manual Products by Nasco NP182_14_LF03840_ArticulatingLegs.indd 1 9/30/15 9:00 AM...
  • Page 2 NP182_14_LF03840_ArticulatingLegs.indd 2 9/30/15 9:00 AM...
  • Page 3 Leg Skin Pads (4) Pint Bottle with Blood Powder 15-Gauge IO Needle Black Shorts (1 pair) Actual product may vary slightly from photo. Nasco reserves the right to change product color, materials, supplies, or function as needed. NP182_14_LF03840_ArticulatingLegs.indd 3 9/30/15 9:00 AM...
  • Page 4 Figure 1 Figure 2 Setup Attaching the Legs Match up the keyhole on the pelvic piece with the keyhole toward the top of the hip joint piece. (See figure 1.) Figure 3 Align the keyholes and slide the assembled leg into the pelvic piece.
  • Page 5 Figure 5 Figure 6 Secure the screw with a nut on the inside of the torso shell. Tighten down the nuts finger tight. DO NOT OVER TIGHTEN. (See figure 5.) Replace load box, compression springs, upper compression plate, chest plate, chest skin, and clothing.
  • Page 6 Figure 10 Figure 11 Place simulator on a flat sur- face such as a tabletop. Fill the 60 cc syringe by plac- ing the tubing end of the syringe into the pint bottle of blood mixture and drawing the blood mixture up into the syringe.
  • Page 7 Care and Maintenance Nasco recommends the use of Nasco Cleaner LF09919U for cleaning the articulating legs, pelvic piece, and pelvic cap. CAUTION: Soap and water may be used to clean the pelvic region, legs, right IO lower leg, and feet.
  • Page 8 Right Upper Leg LF04067(N)U Left Lower Leg LF04069(N)U Ankle LF04094(N)U Complete Left Leg LF09919U Nasco Cleaner Actual product may vary slightly from photo. Nasco reserves the right to change product color, materials, supplies, or function as needed. NP182_14_LF03840_ArticulatingLegs.indd 8 9/30/15 9:01 AM...
  • Page 9 LF04084U Edema Foot LF04041U Pressure Ulcer Foot LF04041U LF03943U Fort Atkinson 901 Janesville Avenue, P .O. Box 901 Fort Atkinson, Wisconsin 53538-0901 1.800.558.9595 eNasco.com • E-mail: lifeform@eNasco.com COPYRIGHT © NASCO 2014 PRINTED IN U.S.A. NP 182-14/RV 9-15 NP182_14_LF03840_ArticulatingLegs.indd 10 9/30/15 9:02 AM...