BARISTA FREESTANDING/SQUARE REFRIGERATED Warnings Operational This appliance is not intended for use by young children or infirm persons, Safety unless they have been adequately supervised by a responsible person, to ensure that they can use the appliance safely. Young children should be supervised, to ensure that they do not play with the appliance.
REFRIGERATED INTRODUCTION Welcome REFRIGERATED CABINETS - INTRODUCTION Future Welcome to the world of FPG! Our products are designed and engineered to Products give you the optimal performance that you deserve with innovative visual Group (FPG) merchandising appeal. We are confident that you will be delighted with your state of the art inline food service cabinet, and that it will become a valued appliance in your store.
• Fair wear and tear. Assessment The liability under this warranty is dependent on an assessment by FPG, to determine the defect in workmanship or materials. Time Limit FPG does not guarantee that any service to be performed under this warranty will be carried out within any particular time limit.
BARISTA FREESTANDING/SQUARE REFRIGERATED OPERATION Cabinet Features REFRIGERATED CABINETS - OPERATION Large Capacity The drawer has a large storage capacity. It can be configured for an asortment of product packaging. Adjustable The inclined, gravity feed base has Guides removeable roller strips. These ensure that product moves to the front.
PRODUCT MANUAL 31693 REV B NOV 2021 Controls REFRIGERATED CABINETS - OPERATION Control Panels The control on the front of the cabinet is fitted with: • A mains Power Switch • A refrigeration controller An acrylic flap protects the controls from accidental spills.
BARISTA FREESTANDING/SQUARE REFRIGERATED Preparation cont. REFRIGERATED CABINETS - OPERATION Power Supply Ensure that power is connected to the cabinet. Close the It is important to keep the drawer closed. Drawer If the drawer is not fully closed, an even temperature will not be maintained within the cabinet.
PRODUCT MANUAL 31693 REV B NOV 2021 TROUBLE SHOOTING FAULT POSSIBLE CAUSE REMEDY The mains isolating switch on Turn isolating switch circuit the wall, circuit breaker or fuses breaker or fuses on are off at the power board Switch cabinet off and on. Cabinet does not High temperature detected Clean condenser and radiator...
BARISTA FREESTANDING/SQUARE REFRIGERATED Fault Alarms REFRIGERATED CABINETS - TROUBLE SHOOTING Fault Indication The controller will generate up to 4x different alarms. When a fault is detected the alarm code will alternate with the cabinet temperature on the controller display. The alarm bell icon will remain lit up on the controller display while the alarm is present Alarm Codes E29 = Control probe faulty.
PRODUCT MANUAL 31693 REV B NOV 2021 CLEANING Cautions REFRIGERATED CABINETS - CLEANING Power ALWAYS TURN THE POWER SUPPLY OFF BEFORE CLEANING. Water THIS UNIT IS NOT WATERPROOF. DO NOT USE A WATER JET SPRAY TO CLEAN THE INTERIOR OR EXTERIOR OF THIS CABINET. Exterior REFRIGERATED CABINETS - CLEANING Plastic and...
BARISTA FREESTANDING/SQUARE REFRIGERATED Interior REFRIGERATED CABINETS - CLEANING Empty the Do NOT remove the drawer for Drawer routine cleaning. Open the drawer fully, and remove all products. Lift Out Plastic The roller strips just rest on the Guide inclined base tray, and can be lifted out for cleaning.
PRODUCT MANUAL 31693 REV B NOV 2021 Cleaning Routines REFRIGERATED CABINETS - CLEANING Schedules Regular cleaning schedules are required to maintain optimum performance. Failure to carry out routine cleaning/servicing schedules will void the warranty on the refrigeration equipment. Removable The air pre-filter must be kept Filter clean, to maintain efficient refrigeration performance.
BARISTA FREESTANDING/SQUARE REFRIGERATED INSTALLATION Regulations REFRIGERATED CABINETS - INSTALLATION Compliance It is very important that your cabinet is installed correctly and that the operation with Local is correct before use. Installation must comply with local electrical, health & Requirements safety and hygiene requirements. Setting Up REFRIGERATED CABINETS - INSTALLATION Unpacking...
PRODUCT MANUAL 31693 REV B NOV 2021 Setting Up cont. REFRIGERATED CABINETS - INSTALLATION Condensate The condensate drain outlet must be connected to a suitable drain. Exit holes Drain are provided underneath, and on either side and rear of the cabinet. A P-trap must be included in the piping, to prevent contaminated air from entering the cabinet.
BARISTA FREESTANDING/SQUARE REFRIGERATED SERVICING Control Gear REFRIGERATED CABINETS - SERVICING Control Gear All control gear is located in the Location box behind the mains switch. Hinge down the spring-loaded front panel to access it. Remove two screws to release the back panel. Control Gear The chassis houses the connecting blocks for the Chassis...
PRODUCT MANUAL 31693 REV B NOV 2021 Refrigeration REFRIGERATED CABINETS - SERVICING Caution DO NOT attempt to service the refrigeration equipment without isolating the cabinet at the main switch or unplugging it from the wall. Removable The cabinet is fitted with a removable Filters filter, which will catch most of the dust and fluff, before it reaches the condenser...
BARISTA FREESTANDING/SQUARE REFRIGERATED Refrigeration cont. REFRIGERATED CABINETS - SERVICING Support Bolt The support bolt must be unscrewed if the cabinet is to be removed from the joinery, or access to the evaporator fans, coil or probes is required. Evaporator The drawer must be removed to access Access the evaporator fans, coil and temperature probes.
PRODUCT MANUAL 31693 REV B NOV 2021 Refrigeration cont. REFRIGERATED CABINETS - SERVICING Temperature Model ERC 214 is a microprocessor-based Regulator controller. Danfoss It has three NTC probe inputs, the first one ERC 214 for temperature control, the second one, located onto the evaporator, to control the defrost termination temp, and the third one to detect the compressor temperature.
Climate Class 4 +2° to +4°C 30°C Ambient 55% RH Improvements REFRIGERATED CABINETS - SPECIFICATIONS On-going FPG reserves the right to change specifications and construction, as part of on- Development going product improvement. PRODUCT MANUAL 31693 / REV B / NOV 2021...
Number the label fixed to the control panel. This serial number will enable FPG to trace details of the build specification of your particular cabinet, and hence ensure that spare parts are fully compatible. To satisfy warranty conditions, and ensure optimum performance, use only FPG supplied spare parts.
Page 31
BARISTA FREESTANDING/SQUARE REFRIGERATED PRODUCT MANUAL 31693 / REV B / NOV 2021...
Page 32
PRODUCT MANUAL 31693 REV B NOV 2021 In line with our policy to continually develop, improve and support our products, Future Products Group Ltd reserves the right to change specifications and design without notice. Have a question? Please email us at support@fpgworld.com or visit WWW.FPGWORLD.COM...