Rate - 26,000 Btuh Only - Carrier 916SA Installation, Start-Up, Operating And Service And Maintenance Instructions

Single-stage, high efficiency, 4-way multipoise 35-in. (889 mm), condensing gas furnace
Table of Contents

Advertisement

916SA: Installation, Start-up, Operating and Service and Maintenance Instructions
Table 25 – Orifice Size and Manifold Pressure (in. w.c.) for Gas
Input Rate - 40,000 BTUh to 140,000 BTUh
SINGLE-STAGE FURNACE
(TABULATED DATA BASED ON 20,000 BTUH PER BURNER, DERATED 2%/1000 FT (305M) ABOVE SEA LEVEL)
ALTITUDE
A
V
. G
G
A
S
RANGE
HEAT VALUE
0.58
AT ALTITUDE
Orifice
Manifold
ft (m)
(Btu/cu ft)
No.
Pressure
900
43
0
925
43
(0)
950
43
975
44
to
1000
44
1025
44
2000
1050
44
(610)
1075
45
1100
46
U.S.A.
800
42
2001 (611)
825
43
to
850
43
3000 (914)
875
43
900
44
Canada
925
44
2001 (611)
950
44
to
975
44
4500 (1372)
1000
44
775
42
3001
800
43
(915)
825
43
850
44
to
875
44
4000
900
44
(1219)
925
44
950
44
750
42
4001
775
43
(1220)
800
43
825
44
to
850
44
5000
875
44
(1524)
900
44
925
44
725
42
5001
750
43
(1525)
775
43
800
44
to
825
44
6000
850
44
(1829)
875
44
900
44
675
42
6001
700
42
(1830)
725
43
750
43
to
775
44
7000
800
44
(2133)
825
44
850
44
SINGLE-STAGE FURNACE
(TABULATED DATA BASED ON 20,000 BTUH PER BURNER, DERATED 2%/1000 FT (305M) ABOVE SEA LEVEL)
ALTITUDE
A
V
G
.
G
A
S
RANGE
HEAT VALUE
0.58
AT ALTITUDE
Orifice
Manifold
ft (m)
(Btu/cu ft)
No.
Pressure
650
42
7001
675
43
(2134)
700
43
725
44
to
750
44
8000
775
44
(2438)
800
44
825
44
625
42
8001
650
43
(2439)
675
43
700
44
to
725
44
9000
750
44
(2743)
775
44
9001
600
42
(2744)
625
43
650
43
to
675
44
10000
700
44
(3048)
725
44
* Orifice numbers shown in BOLD are factory-installed.
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
S
P
E
C
F I
C I
G
R
A
V
T I
Y
O
F
N
A
T
U
R
A
L
G
A
S
0.60
0.62
Orifice
Manifold
Orifice
Manifold
Orifice
No.
Pressure
No.
Pressure
No.
3.8
42
3.2
42
3.3
3.6
43
3.7
43
3.8
3.4
43
3.5
43
3.6
3.7
44
3.8
43
3.4
3.5
44
3.6
44
3.8
3.3
44
3.5
44
3.6
3.2
44
3.3
44
3.4
3.7
45
3.8
44
3.3
3.7
46
3.8
45
3.8
3.4
42
3.5
42
3.6
3.8
42
3.3
42
3.4
3.6
43
3.7
42
3.2
3.4
43
3.5
43
3.7
3.7
44
3.8
43
3.5
3.5
44
3.6
44
3.8
3.3
44
3.4
44
3.6
3.2
44
3.3
44
3.4
3.0
44
3.1
44
3.2
3.3
42
3.4
42
3.5
3.8
42
3.2
42
3.3
3.6
43
3.7
43
3.8
3.8
43
3.5
43
3.6
3.6
44
3.7
43
3.4
3.4
44
3.5
44
3.7
3.2
44
3.4
44
3.5
3.1
44
3.2
44
3.3
3.3
42
3.4
42
3.5
3.7
43
3.8
42
3.3
3.5
43
3.6
43
3.7
3.8
43
3.4
43
3.5
3.5
44
3.7
44
3.8
3.3
44
3.5
44
3.6
3.2
44
3.3
44
3.4
3.0
44
3.1
44
3.2
3.2
42
3.3
42
3.4
3.7
43
3.8
42
3.2
3.4
43
3.5
43
3.7
3.7
44
3.8
43
3.4
3.5
44
3.6
44
3.7
3.3
44
3.4
44
3.5
3.1
44
3.2
44
3.3
2.9
44
3.0
44
3.1
3.4
42
3.5
42
3.6
3.2
42
3.3
42
3.4
3.6
43
3.7
43
3.8
3.4
43
3.5
43
3.6
3.6
44
3.7
43
3.4
3.4
44
3.5
44
3.6
3.2
44
3.3
44
3.4
3.0
44
3.1
44
3.2
S
P
E
C
F I
C I
G
R
A
V
T I
Y
O
F
N
A
T
U
R
A
L
G
A
S
0.60
0.62
Orifice
Manifold
Orifice
Manifold
Orifice
No.
Pressure
No.
Pressure
No.
3.4
42
3.5
42
3.6
3.8
42
3.2
42
3.3
3.5
43
3.7
43
3.8
3.8
43
3.4
43
3.5
3.5
44
3.7
44
3.8
3.3
44
3.4
44
3.5
3.1
44
3.2
44
3.3
2.9
44
3.0
44
3.1
3.4
42
3.5
42
3.6
3.8
42
3.2
42
3.3
3.5
43
3.6
43
3.7
3.7
43
3.4
43
3.5
3.5
44
3.6
44
3.7
3.3
44
3.4
44
3.5
3.0
44
3.2
44
3.3
3.3
42
3.4
42
3.6
3.7
42
3.2
42
3.3
3.5
43
3.6
43
3.7
3.7
44
3.8
43
3.4
3.4
44
3.5
44
3.7
3.2
44
3.3
44
3.4
Table 26 – Orifice Size and Manifold Pressure (in. w.c.) for Gas
0.64
Manifold
Pressure
42
3.4
42
3.2
43
3.7
43
3.6
43
3.4
44
3.7
44
3.5
44
3.4
44
3.2
42
3.7
42
3.5
42
3.3
43
3.8
43
3.6
43
3.4
44
3.7
44
3.5
44
3.3
42
3.6
42
3.4
42
3.2
43
3.7
43
3.5
44
3.8
44
3.6
44
3.4
42
3.6
42
3.4
43
3.8
43
3.6
43
3.4
44
3.7
44
3.5
44
3.3
42
3.5
42
3.3
43
3.8
43
3.5
44
3.8
44
3.6
44
3.4
44
3.2
42
3.8
42
3.5
42
3.3
43
3.7
43
3.5
44
3.7
44
3.5
44
3.3
A11253A
0.64
Manifold
Pressure
42
3.7
42
3.4
42
3.2
43
3.6
43
3.4
44
3.7
44
3.4
44
3.2
42
3.7
42
3.4
42
3.2
43
3.6
44
3.8
44
3.6
44
3.4
42
3.7
42
3.4
43
3.8
43
3.5
44
3.8
44
3.5
A11253B
3. Restore furnace to normal operating condition.
a. Turn gas valve ON/OFF switch to OFF.
b. Remove water column manometer or similar device from
manifold pressure tap.
60
Input Rate - 26,000 BTUh ONLY
A150571
A150572

Advertisement

Table of Contents
loading