esera automation Auto-E-Connect 11230 User Manual

4-fold analog input insulated for 1-wire bus

Advertisement

Quick Links

Art. No. 11230
4
input channels with 0-10VDC measuring range
electrical insulation between analog and Bus area
analog converter with high 12-bit resolution
analog inputs with overvoltage protection
input filter for "calmed" measured value acquisition
DIN rail housing for control cabinet installation according to
DIN EN 50022
screw terminal connection
easy to assemble
housing colour green
1

Introduction

Before you start the installation of the 4-fold analog input and put the device into operation, please read these
installation and operating instructions carefully to the end, especially the section referring to the safety
instructions.
2

Product description

With the 4-fold analog input insulated, sensors with DC voltage output such as pressure sensors, light
sensors, setpoint generators or other sensors with 0-10V output voltage with galvanic isolation can be easily
measured. The triggering of the analog converter is fixed at 12Bit.
With the 4-fold analog input insulated DC voltages or sensors can be monitored with low load of the sensor.
The 4 input channels are galvanically insulated from the 1-wire bus and the supply voltage. This allows analog
signals from sensors or modules to be measured with different potentials. The isolation avoids effects caused
by ground loops due to potential differences. In order to obtain "calm measured values", the module has
optimally adapted filters in the input area.
The input channels have a common ground potential. If different analog signals with different potentials are to
be measured, separate modules must be provided.
We will be pleased to advise you on the possible applications.
3
Auto-E-Connect® Support
The ESERA Auto-E-Connect® 1-Wire Plug and Play system will be used for the
1-Wire Bus supported. This enables fully automatic configurations of 1-Wire sensors
and actuators on the 1-Wire bus. It is optimized for industrial applications and
enables significant added value beyond the sensor and chip data.
The Auto-E-Connect function automatically recognizes ESERA chips, sensors and actuators, starts suitable
libraries and outputs fully formatted data.
The Auto-E-Connect functionality will be available from mid-2020 via 1-Wire Controllers, 1-Wire Gateways and
1-Wire ECO from ESERA available. Further information on ESERA Auto-E-Connect can be found on the
ESERA website, ESERA Config-Tool 3, or in the download area for this article in the ESERA Webshop.
All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of
ESERA GmbH. Errors and technical modification subject to change. ESERA GmbH, ESERA-Automation 2020
www.esera.de
User Guide
4-fold analog input insulated
for 1-Wire Bus
11230 V2.0 R1.0 Manual
Page 1 of 6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Auto-E-Connect 11230 and is the answer not in the manual?

Questions and answers

Summary of Contents for esera automation Auto-E-Connect 11230

  • Page 1 Art. No. 11230 User Guide 4-fold analog input insulated for 1-Wire Bus  input channels with 0-10VDC measuring range  electrical insulation between analog and Bus area  analog converter with high 12-bit resolution  analog inputs with overvoltage protection ...
  • Page 2 Technical data Analog inputs: Resolution: Resolution 12Bit fix, ca. 3mV Number of input channels: 4 x analog input 0-10VDC Measuring range: 0 - 10VDC Max. input voltage: 12V (overvoltage protection) Insulation: Isolation of the input section from the 1-Wire bus. All analog inputs have a common ground potential.
  • Page 3 Art. No. 11230 Connection - Example Please refer to the following connection example with 1-Wire Controller or 1-Wire Gateway, 4-fold analog input and Dual S0-Counter. All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of ESERA GmbH.
  • Page 4 LED indicator The module has a green LED indicator which lights up when the module is supplied with 12V operating voltage. Indicator Designation Function  Lights up permanently as an indicator for operational readiness. LED green Power Software / Control The block is controlled by a 1-Wire command for the DS2450 block.
  • Page 5 Art. No. 11230 Integration in FHEM For the integration into the open source automation software FHEM we provide a software module for easy integration of the 4-fold analog input into FHEM via 1-Wire Controller / 1-Wire Gateway. This eliminates the need for evaluation scripts.
  • Page 6  If measurements with an open housing are unavoidable, for safety reasons an isolating transformer must be installed upstream or a suitable power supply can be used.  After installing the required tests according to DGUV / regulation 3 (German statutory accident insurance, https://en.wikipedia.org/wiki/German_Statutory_Accident_Insurance) must be carried out.

Table of Contents