Example:AT+TMCFG=0
Note:1.The coordinator and node should have the same transmission mode before they can access the network.
2. E70 (915NW30S) has no standard transmission mode. Configure AT + TMCFG = 0 or AT + TMCFG = 1, and
their modes are long-distance mode.)
3. After setting the transmission mode, the network information will be cleared
AT+ PIDCFG Set/Query PANID configuration(restart to take effect)
9
AT+PIDCFG=Value
Example:AT+PIDCFG=65535
Note: 1. The node can only join the same network as its PANID (any network can be added when it is configured as 65535)
2. After setting PANID,the network information will be cleared
AT+ DMCFG Set/Query device sleep time configuration(restart to take effect)
10
AT+DMCFG=Value
Example:AT+DMCFG=0
Note: When set to 0, the sleep node can never receive data from the coordinator and can only upload data to the
coordinator, but the sleep node cannot automatically determine that it is disconnected from the network, it can only
determine that it is disconnected from the network after ten failed communications.
AT+RSCFG Set / Query device auto restart parameter configuration(restart to take effect)
11
Example:AT+RSCFG=60
Note: This parameter can be used for node disconnection detection.
AT+UBCFG Set / Query serial baud rate parameter configuration(restart to take effect)
12
Example:AT+UBCFG=7
Chengdu Ebyte Electronic Technology Co.,Ltd
Copyright ©2012–2019,
AT+PIDCFG=?
AT+DMCFG=?
AT+RSCFG=?
AT+RSCFG=Value
AT+UBCFG=?
AT+UBCFG=Value
Parameter specification:
Acquire the current device's PANID configuration
Response:
PIDCFG:65535
Parameter specification:
Value:0~65535,Factory default PANID parameter is 65535
Parameter specification:
Acquire the current device sleep time configuration
Response:
DMCFG:0 or 2~30
Parameter specification:
Value:Sleep time, unit ( S), Can be set to 0 or 2~30 seconds,
Factory default parameter is 6(S)
Parameter specification:
Acquire the current device auto restart parameter configuration
Response:
RSCFG:0
Parameter specification:
Value: 60~65535 (S) , Factory default parameter is 60 (S)
Parameter specification:
Acquire the current device serial baud rate parameter
configuration
Response:
UBCFG:7
Parameter specification:
Value:0~7
0:1200
1:2400
2:4800
3:9600
4:19200
5:38400
6:57600
7:115200(Factory default)