5
4
6
6. Remove the side cover screws, and then remove
the side cover.
4 Side cover screw
5 Side cover
4
788-014
7. Drain the fuel remaining in the carburetor into an
approved container by loosening the drain screw
on the carburetor float chamber.
6 Drain screw
8. Tighten the drain screw.
707-109b
9. Turn the engine switch to "5" (STOP).
10. Turn the fuel cock lever to OFF.
11. Install the side cover and tighten the side cover
screws.
12. Tighten further if any screws, bolts and nuts are
loose.
13. Store the generator in a dry, well-ventilated place,
with the cover placed over it.