Download Print this page
XCHARGE C6EU Preventive Maintenance Instructions

XCHARGE C6EU Preventive Maintenance Instructions

Dc charging station
Hide thumbs Also See for C6EU:

Advertisement

Quick Links

XCHARGE C6EU DC charging station
Preventive maintenance instructions
Category
External monitoring of
EVSE
Checking the display and
control panel
Checking the door
mechanism
Inspection of internal
covers
Replacing the filter mats
Visual component
inspection
Checking the cables
XCHARGE Europe GmbH, Borsteler Bogen 27 A, 22453 Hamburg, Germany
Maintenance by maintenance partners / XCHARGE
Predefined
maintenance
work duration
cycles
1 year
1 year
1 year
1 year
1 year
1 year
1 year
Expected
Checking the body of EVSE for scratches and damage caused
2 min.
1 min.
Check that the display and control panel are not damaged.
Checking the locking mechanism of the front and rear doors,
2 min.
i.e. fixing points, handle and lock. Check that the whole lo-
Check the internal protection covers and enclosures of the
12 min.
EVSE. Please pay attention to dirt, penetrated water and cor-
rosion. Please remove dust in the charger (if present).
Replace the filter mats if cleaning does not restore the
function. Otherwise, check the cleanliness. Cleaning must be
10 min.
carried out (if necessary) in such a way that the filters are not
Check that all components are marked as they were when
4 min.
the machine was commissioned and are not in the event of a
fault. Please check for damage and corrosion.
Check that all cables are marked as at commissioning, please
7 min.
check for damage and loose connections. The valid safety
rules must be followed and insulated tools must be used.
Description
by transport or vandalism.
cking system works well.
damaged.
http://www.xcharge.com/en/

Advertisement

loading

Summary of Contents for XCHARGE C6EU

  • Page 1 Check that all cables are marked as at commissioning, please Checking the cables 1 year 7 min. check for damage and loose connections. The valid safety rules must be followed and insulated tools must be used. XCHARGE Europe GmbH, Borsteler Bogen 27 A, 22453 Hamburg, Germany http://www.xcharge.com/en/...
  • Page 2 3 years 20 min. Check that the insulation resistance between the wires is > rectifier modules, discon- 1MΩ at 500VDC. nection of the control unit) XCHARGE Europe GmbH, Borsteler Bogen 27 A, 22453 Hamburg, Germany http://www.xcharge.com/en/...
  • Page 3 EVSE. All results should be written down in the table and sent annually to eu@xcharge.com to demonstrate proper maintenance of the charging station. XCHARGE's warranty is void if the charging station has not been properly maintained.

This manual is also suitable for: