TX
INDICATOR
USER MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Gram ACCUREX TX

  • Page 1 INDICATOR USER MANUAL...
  • Page 3 INDEX 1. Main specifications 2. Keyboard 2.1. Keyboard 2.2. Keyboard function 3. Connection of load cells to the indicator 4. Instructions for use and description 4.1. Tare 4.2. Zero 4.3. Animal weighing function 4.4. Accumulation function 4.5. Upper and lower limit alarm settings 5.
  • Page 5: Main Specifications

    1. Main specifications 1. Model: TX Digital Weighing Indicator 2. Sample rate: 10-20 times/second 3. Sensitivity of load cell: 1.5~3mV / V 4. Interval: 1/2/5/10/20/50 (Configurable) 5. Display: 6-digit LED display with 10 status indicators 8. Power supply: 100-240Vac/50-60Hz - 12Vdc-500mA AC/DC adapter 18659 3,7V 4000mAh Rechargeable Li-Ion Battery 9.
  • Page 6 2.2. Keyboard function Function Press this key to turn the display on/off. Press and hold this button for more than 5 seconds in weighing mode, you will enter user parameter setting mode; press and hold this button for less than 5 seconds, you will enter a ales weighing mode. In weighing mode, press this button to accumulate the weight;...
  • Page 7 Instructions for use and description 4.1. Tare Place the load to be weighed on the scale platform, when the stability indicator lights up, press the key to tare. The display shows zero and the net weight indicator light comes on. Remove the load and press again the key to cancel the tare, the net weight indicator light will disappear.
  • Page 8: System Setup

    5. System setup In the weighing mode, press and hold down the key to enter the user configuration mode. Press the key to change the value. Press the key to enter the next parameter; when all parameters have been set, press the key to exit the user configuration mode.
  • Page 9 Display Function Parameter Instructions 2% Max 4% Max 10% Max Initial zeroing [P9 1] configuration 20% Max 100% Max Disabled Fast Digital filter time Intermediate [P10 1] intensity Fast Time of stability Intermediate [P11 1] Range of stability Medium [P12 1] High Medium Setting the animal...
  • Page 10: Use Of Battery

    6. Failure and correction Display Instructions The AD value is too small when calibrated or the load cell capacity is Err1 too large. Zero point is out of range when calibrating. Err2 The zero point is out of range at start-up or there is too much weight Err3 on the scale.
  • Page 11: Maintenance And Precautions

    8. Maintenance and precautions • In order to extend the life of the weight indicator it should not be installed in direct sunlight. • Avoid installing the scale in humid environments and keep it isolated from severe vibrations. • Do not use strong solvents such as benzene and nitro based oils to clean the housing. •...
  • Page 12 9.3. Press the to enter the Maximum Capacity setting. Press to change digit, press the key to change the value. Display Parameter Press the key to enter the maximum capacity setting. [FULL] Press the key to move the digit from left to right. When the number flashes, press the key to add 1 value to the flashing [2000.0]...
  • Page 14 02/23032023 Gram Precision S.L. Travesía Industrial, 11 · 08907 Hospitalet de Llobregat · Barcelona (Spain) Tel. +34 902 208 000 · +34 93 300 33 32 Fax +34 93 300 66 98 gram.es comercial www.gram-group.com...