Mitsubishi Electric MUZ-LN35VGHZ2-E1 Service Manual page 83

Outdoor unit
Table of Contents

Advertisement

OPERATING PROCEDURE
Connection procedure when attaching the inverter P.C.
*
board (Photo 6, 7)
1. Attach the heat sink support to the P.C. board support.
2. Hook the lead wires of the compressor, the reactor and
the P.C. board to each hooks on the heat sink support as
shown Photo 7.
3. Connect the lead wires of the expansion valve coil to the
connector on the inverter P.C. board. Pull the lead wires of
the expansion valve coil toward you and put them on the
left hook on the P.C. board support as shown in Photo 6.
Photo 7
Hook of the lead wires
of the P.C. board
Inverter P.C. board
OBH768G
Hook of the lead
wires of the reactor
Hook of the lead wires
of the compressor
83
PHOTOS/FIGURES
Photo 5
Screws of the earth wires and
the terminal block support
Photo 6
Lead wires of the
expansion valve coil
Inverter P.C. board support
Screws of the
terminal block
support