Mitsubishi Electric MUZ-LN35VGHZ2-E1 Service Manual page 82

Outdoor unit
Table of Contents

Advertisement

OPERATING PROCEDURE
2. Removing the inverter assembly and inverter P.C.
board
(1) Remove the cabinet and panels. (Refer to section 1.)
(2) Disconnect the lead wire to the reactor and the following
connectors:
<Inverter P.C. board>
CN602 (R.V. coil)
CN931, CN932 (Fan motor)
CN671 (Defrost thermistor, discharge temperature thermistor
and outdoor heat exchanger temperature thermistor)
CN672 (Ambient temperature thermistor)
CN724 (Expansion valve coil)
CN64 (Compressor protector)
(3) Remove the compressor connector (CN61).
(4) Remove the screws fixing the heat sink support and the
separator.
(5) Remove the screws fixing the P.C. board support and the
motor support.
(6) Remove the fixing screws of the terminal block support and
the back panel.
(7) Remove the inverter assembly.
(8) Remove the screws of the earth wire.
(9) Remove the screw of the heat sink support, and the heat
sink support from the P.C. board support.
(10) Remove the screws of the terminal block support, and the
screws of the earth wires and the terminal block support.
(Photo 5)
(11) Remove the terminal block support.
OBH768G
PHOTOS/FIGURES
Photo 3
Screw of the heat sink
support and the separator
Screw of the
P.C. board
support and
the motor
support
Connector of compressor protector
Photo 4 (Inverter assembly)
P.C. board support
Heat sink
Screws of the
support
earth wire
Heat sink
Screw of the heat
sink support
Inverter P.C. board
82
Lead wires of the
reactor
Screws of
the terminal block
support and
the back panel
Screw of the
earth wires and
the terminal
block support
Screw of the
earth wires and
the terminal
block support

Advertisement

Table of Contents
loading

Table of Contents