REFRIGERANT SYSTEM DIAGRAM

MUZ-LN25VGHZ
MUZ-LN25VGHZ2 MUZ-LN35VGHZ2
Refrigerant pipe ø9.52
(with heat insulator)
Flared connection
Flared connection
Refrigerant pipe ø6.35
(with heat insulator)
MUZ-LN50VGHZ
Refrigerant pipe ø9.52
(with heat insulator)
Flared connection
Flared connection
Refrigerant pipe ø6.35
(with heat insulator)
OBH768G
MUZ-LN35VGHZ
Muffler
Stop valve
Stop valve
Capillary tube
(with strainer)
ø4.0×ø2.4×240
Strainer
#100
Stop valve
Strainer
#100
Stop valve
4-way valve
Muffler
Discharge
temperature
thermistor
RT62
Compressor
Defrost
thermistor
RT61
LEV
4-way valve
Discharge
temperature
thermistor
Defrost
RT62
thermistor
RT61
Compressor
LEV
Capillary tube
Strainer
ø4.0×ø2.4×100
#100
Muffler
21
Outdoor heat
exchanger
temperature
thermistor
Outdoor
RT68
heat
exchanger
Ambient
temperature
thermistor
RT65
Strainer
#100
R.V. coil
heating ON
cooling OFF
Refrigerant flow in cooling
Refrigerant flow in heating
Outdoor
heat
Ambient
exchanger
temperature
thermistor
RT65
Outdoor heat
exchanger
temperature
thermistor
RT68
R.V. coil
heating ON
cooling OFF
Refrigerant flow in cooling
Refrigerant flow in heating
Unit: mm