Download Print this page

Infrared Dynamics Sunpak S25S Installation, Operation And Maintenance Instructions

Outdoor gas infrared patio heater

Advertisement

Quick Links

Installer: Please take the time to read and understand these instructions prior to installation. Installer
must provide a copy of this manual to the owner.
Owner: Keep this manual in a safe place in order to provide your service technician with the
necessary information.
Warning:
These instructions are intended for qualified personnel, specifically trained and experienced in the
installation and repair of this type of equipment and related system components.
IF NOT INSTALLED, OPERATED AND MAINTAINED IN ACCORDANCE WITH THE
MANUFACTURER'S INSTRUCTIONS, THIS PRODUCT CAN EXPOSE YOU TO
SUBSTANCES IN THE FUEL OR FROM COMBUSTION INCLUDING CARBON
MONOXIDE, RESULTING IN DEATH OR SERIOUS ILLNESS AND WHICH ARE
KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS
OR REPRODUCTIVE HARM.
For more information go to www.P65WARNINGS.CA.GOV
Infrared Dynamics, Inc © Copyright 2018
Printed in USA
Sunpak Models S25 & S34
Installation, Operation and & Maintenance Instructions
WARNING: California Proposition 65
Outdoor Gas Infrared Patio Heater
NOT FOR USE IN RESIDENTIAL DWELLINGS
Infrared Dynamics, Inc
3830 Prospect Avenue
Yorba Linda, CA 92886
http:\\sunpak.us
For Local Distributor Listing
Call Us Toll Free (888) 317-5255
Form No 62047 – 8/18

Advertisement

loading

Summary of Contents for Infrared Dynamics Sunpak S25S

  • Page 1 For more information go to www.P65WARNINGS.CA.GOV Infrared Dynamics, Inc 3830 Prospect Avenue Yorba Linda, CA 92886 http:\\sunpak.us For Local Distributor Listing Call Us Toll Free (888) 317-5255 Infrared Dynamics, Inc © Copyright 2018 Form No 62047 – 8/18 Printed in USA...
  • Page 2 Sunpak® S25 & S34 Infrared Heaters Table of Contents Sunpak heaters work like the sun Warnings projecting radiant heat down to warm your patio and guests. This heater was 2. Basic Operation designed for outdoor installation; 3. Heater Layout and Design however, breezes will affect the heating 4.
  • Page 3 Sunpak® S25 & S34 Infrared Heaters Basic Heater Operation Sunpak Heaters ® Sunpak Heaters are available with two different input rates. The Model S25, rated at 25,000 Btu/Hr, allows people to be comfortable at lower mounting heights. The model S34, rated 34,000 Btu/Hr, requires greater clearance from combustible material, and it is comfortable at greater mounting heights (see page 4).
  • Page 4 Sunpak® S25 & S34 Infrared Heaters Patio Design Consideration Heater Layout and Design Heater placement is critical for effective and efficient ® Sunpak heaters were specifically designed to provide patio heating. If heaters are placed too close together or heated comfort in an outdoor environment. They have been mounted too low, people become uncomfortable.
  • Page 5 Sunpak® S25 & S34 Infrared Heaters...
  • Page 6 Sunpak® S25 & S34 Infrared Heaters Warning: Heater must be level in the lengthwise direction.
  • Page 7 Sunpak® S25 & S34 Infrared Heaters Gas Supply Installation/Service Instructions The gas inlet supply pressure and manifold pressures required Receiving Equipment for each heater are listed below. For gas supply line pressures in excess of ½ PSI, consult with your gas service provider or the On receipt of equipment it is suggested that a visual inspection be made for external damage to the carton.
  • Page 8 Sunpak® S25 & S34 Infrared Heaters Gas Piping A minimum pipe size of ½” is required for inlet piping. A ½” lever handled gas shut-off valve should be installed within 6 feet of the appliance for servicing and as emergency shutoff to the unit. Check with local and state plumbing and heating codes regarding sizing of gas lines.
  • Page 9 Sunpak® S25 & S34 Infrared Heaters Ventilation It is required that areas above the heater be properly vented to allow for necessary Regular Service and Maintenance combustion air and removal of combustion gases. Over time, particularly during long periods of non-use, Heaters shall be provided with natural or mechanical means to supply and exhaust at least the heater can accumulate dirt and debris in and...
  • Page 10 Sunpak® S25 & S34 Infrared Heaters Optional Face Trim can be easily installed on all Sunpak models You must remove the Sunpak Face Trim to connect power to the heater. The Sunpak Face Trim is secured with four (4) screws, two (2) located along each side of the heater.
  • Page 11 Sunpak® S25 & S34 Infrared Heaters...
  • Page 12 Sunpak® S25 & S34 Infrared Heaters...
  • Page 13 Sunpak® S25 & S34 Infrared Heaters...
  • Page 14 Sunpak® S25 & S34 Infrared Heaters Basic S25 & S34 Trouble Shooting Problem Possible Causes How to Fix References No Spark to pilot No power from transformer • Replace Transformer • Electrical – Page 8 Switch is On No power to the heater •...
  • Page 15 THIS WARRANTY IS APPLICABLE TO THE ORIGINAL OWNER ONLY, in accordance with the warranty terms and conditions specified below. Infrared Dynamics (the warrantor) will furnish at our option the ORIGINAL OWNER, 1) a replacement Infrared Dynamics’ heater or 2) a replacement part for any component part which fails before one year when for residential use.

This manual is also suitable for:

Sunpak s34Sunpak s25Sunpak s34s