OVER 60 YEARS OF STEAM SHOWER INNOVATION

Advertisement

loading
Need help?

Need help?

Do you have a question about the Wellness Steam ThermaTouch7 Hydrovive18 Package and is the answer not in the manual?

Questions and answers

Summary of Contents for Thermasol Wellness Steam ThermaTouch7 Hydrovive18 Package

  • Page 1 Installation Manual For Tutorials and Troubleshooting visit www.thermasol.com/solutions OVER 60 YEARS OF STEAM SHOWER INNOVATION...
  • Page 2 Installation Manual For Tutorials and Troubleshooting visit www.thermasol.com/solutions TT7X-XX OVER 60 YEARS OF STEAM SHOWER INNOVATION...
  • Page 3 NEVER ATTEMPT TO FILL AROMA RESERVOIR ON THE STEAMHEAD WHEN UNIT IS IN THE "ON" POSITION. SEVERE BURNS WILL OCCUR. DO NOT USE THERMASOL AROMATHERAPY OILS, SKIN CARE PRODUCTS OR ANY PRODUCT ASSOCIATED WITH YOUR THERMASOL UNIT WITHOUT CONSULTING WITH YOUR ALLERGIST OR DOCTOR BEFORE USE. THESE PRODUCTS MAY BE HAZARDOUS TO YOUR HEALTH.
  • Page 4 ON THE BACK OF THE CONTROLLER. PRIOR TO INSTALLTION OF YOUR THERMATOUCH LOCATE THE CLOSEST EARTH GROUND (COPPER WATER PIPE) AND ATTACHED THE WIRE AS SHOWN BELOW. IF YOU HAVE ANY QUESITONS ABOUT THIS PROCESS PLEASE CONTACT US AT SUPPORT@THERMASOL.COM OR BY PHONE AT 800.776.0711...
  • Page 5: Tools And Materials

    Shower wall Shower wall Mud Ring goes inside wall opening 7.5" W by 5.5" opening for recessed mount TTMR-BK Mud Ring Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. THERMASOL.COM 800.776.0711...
  • Page 6 Connect the data cable to Power Distribution Module (PDM). (The other end of the cable runs to the back of the control in the shower location.) Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. THERMASOL.COM 800.776.0711...
  • Page 7 Ethernet Cable Connection Grounding Wire Audio Cable Wall Connection Back Side of Surface Side View of Surface Mount Control Mount Control Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. THERMASOL.COM 800.776.0711...
  • Page 8 Connecting ThermaTouch to Serenity Light, Sound, Rainhead 110v M12 Cable Audio Cable T T C S L S M12 Cable Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. THERMASOL.COM 800.776.0711...
  • Page 9 M12 Cable Connecting Total Wellness Package 110v M12 Cable Audio Cable T T C S L S M8 Cable M12 Cable Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. THERMASOL.COM 800.776.0711...
  • Page 10 Shown installed in attic Steam Line 6" 24" Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. THERMASOL.COM 800.776.0711...
  • Page 11 1" socket and driver Steamhead rough-in fitting to be installed flush and sealed to finished wall Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. THERMASOL.COM 800.776.0711...
  • Page 12 Verify control panel lights up and test operation. Note: Initial power-on phase takes several minutes for generator to heat up steam. Please direct the home owner to visit www.thermasol.com/solution and click on the “I’m the home owner” button to learn about set-up and programing (in order to set up the clock and any other options if applicable).
  • Page 13 ThermaTouch Control Installation Instructions Trouble Shooting, Tutorials and Error Codes Visit www.thermasol.com/solutions. Click on Troubleshoot then click on ThermaTouch Control Error Codes. Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details.
  • Page 14 1958 STEAM WAY ROUND ROCK, TX 78665 PHONE: 800.776.0711 | FAX: 800.556.5257 | WWW.THERMASOL.COM 81190_C...
  • Page 15 Installation Manual For Tutorials and Troubleshooting visit www.thermasol.com/solutions HVLSRSQ-XX OVER 60 YEARS OF STEAM SHOWER INNOVATION...
  • Page 16 NEVER ATTEMPT TO FILL AROMA RESERVOIR ON THE STEAMHEAD WHEN UNIT IS IN THE "ON" POSITION. SEVERE BURNS WILL OCCUR. DO NOT USE THERMASOL AROMATHERAPY OILS, SKIN CARE PRODUCTS OR ANY PRODUCT ASSOCIATED WITH YOUR THERMASOL UNIT WITHOUT CONSULTING WITH YOUR ALLERGIST OR DOCTOR BEFORE USE. THESE PRODUCTS MAY BE HAZARDOUS TO YOUR HEALTH.
  • Page 17 Tile Cutter with shut off valve Joist Mounting Bracket + 4x #4 Flat Head Screw Plywood Waterproof Backing Mortar Finished #10 Flat Head Screw Shower Surface RTV Silicone Sealant O-Ring (-016) Screw Cover (Fig. 1) Installation Profile View THERMASOL.COM 800.776.0711...
  • Page 18 25' Yellow M12 Cable single ThermaTouch Control. Item 03-7149-25 ThermaTouch Control sold separately 25' Yellow M12 Cable Item 03-7149-25 ships with ThermaTouch control PDM Sold and ships with ThermaTouch control THERMASOL.COM 800.776.0711...
  • Page 19: Mounting Brackets

    Please be cautious and practice ladder safety. Connecting HydroVive NOTE: Make sure electrical power is off to all ThermaSol devices prior to making any connections. Align the notches at the top of the mounting guides with the mounting brackets and slip them over to firmly secure the HydroVive in place while the connections are made.
  • Page 20: Complete Installation

    NOT OVERTIGHTEN! Once the HydroVive is in position and the silicone seal is created, no further clamping force is necessary. Complete Installation Install the Screw Covers with O-Rings by hand. Allow the silicone to dry for 24 hours before use. THERMASOL.COM 800.776.0711...
  • Page 21 • Increase the separation between the equipment and receiver • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected • Consult the dealer or an experienced radio/TV technician for help THERMASOL.COM 800.776.0711...
  • Page 22 1958 STEAM WAY ROUND ROCK, TX 78665 PHONE: 800.776.0711 | FAX: 800.556.5257 | WWW.THERMASOL.COM 81253_A...