Page 1
Installation Manual For Tutorials and Troubleshooting visit www.thermasol.com/solutions OVER 60 YEARS OF STEAM SHOWER INNOVATION...
Page 2
Installation Manual For Tutorials and Troubleshooting visit www.thermasol.com/solutions TT7X-XX OVER 60 YEARS OF STEAM SHOWER INNOVATION...
Page 3
NEVER ATTEMPT TO FILL AROMA RESERVOIR ON THE STEAMHEAD WHEN UNIT IS IN THE "ON" POSITION. SEVERE BURNS WILL OCCUR. DO NOT USE THERMASOL AROMATHERAPY OILS, SKIN CARE PRODUCTS OR ANY PRODUCT ASSOCIATED WITH YOUR THERMASOL UNIT WITHOUT CONSULTING WITH YOUR ALLERGIST OR DOCTOR BEFORE USE. THESE PRODUCTS MAY BE HAZARDOUS TO YOUR HEALTH.
Page 4
ON THE BACK OF THE CONTROLLER. PRIOR TO INSTALLTION OF YOUR THERMATOUCH LOCATE THE CLOSEST EARTH GROUND (COPPER WATER PIPE) AND ATTACHED THE WIRE AS SHOWN BELOW. IF YOU HAVE ANY QUESITONS ABOUT THIS PROCESS PLEASE CONTACT US AT SUPPORT@THERMASOL.COM OR BY PHONE AT 800.776.0711...
Shower wall Shower wall Mud Ring goes inside wall opening 7.5" W by 5.5" opening for recessed mount TTMR-BK Mud Ring Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. THERMASOL.COM 800.776.0711...
Page 6
Connect the data cable to Power Distribution Module (PDM). (The other end of the cable runs to the back of the control in the shower location.) Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. THERMASOL.COM 800.776.0711...
Page 7
Ethernet Cable Connection Grounding Wire Audio Cable Wall Connection Back Side of Surface Side View of Surface Mount Control Mount Control Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. THERMASOL.COM 800.776.0711...
Page 8
Connecting ThermaTouch to Serenity Light, Sound, Rainhead 110v M12 Cable Audio Cable T T C S L S M12 Cable Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. THERMASOL.COM 800.776.0711...
Page 9
M12 Cable Connecting Total Wellness Package 110v M12 Cable Audio Cable T T C S L S M8 Cable M12 Cable Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. THERMASOL.COM 800.776.0711...
Page 10
Shown installed in attic Steam Line 6" 24" Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. THERMASOL.COM 800.776.0711...
Page 11
1" socket and driver Steamhead rough-in fitting to be installed flush and sealed to finished wall Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. THERMASOL.COM 800.776.0711...
Page 12
Verify control panel lights up and test operation. Note: Initial power-on phase takes several minutes for generator to heat up steam. Please direct the home owner to visit www.thermasol.com/solution and click on the “I’m the home owner” button to learn about set-up and programing (in order to set up the clock and any other options if applicable).
Page 13
ThermaTouch Control Installation Instructions Trouble Shooting, Tutorials and Error Codes Visit www.thermasol.com/solutions. Click on Troubleshoot then click on ThermaTouch Control Error Codes. Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details.
Page 14
1958 STEAM WAY ROUND ROCK, TX 78665 PHONE: 800.776.0711 | FAX: 800.556.5257 | WWW.THERMASOL.COM 81190_C...
Page 15
Installation Manual TDS-3000 OVER 60 YEARS OF STEAM SHOWER INNOVATION...
Page 16
BEFORE USING THE SHOWER, TEST THE WATER TEMPERATURE WITH YOUR HAND BEFORE FULLY ENTERING THE SHOWER. DO NOT USE THERMASOL AROMATHERAPY OILS OR SKIN CARE PRODUCTS OR ANY PRODUCT ASSOCIATED WITH YOUR THERMASOL PRODUCT WITHOUT CONSULTING WITH YOUR ALLERGIST OR DOCTOR BEFORE USE. THESE PRODUCTS MAY BE HAZARDOUS TO YOUR HEALTH.
110V Power Generator TDS-3000 Digital Shower Valve 208/240VAC Easy Start Control Water Inlets Shower Outputs (3) (Outside Shower) (Hot/Cold) Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. THERMASOL.COM I 800.776.0711...
Digital Shower Valve IMPORTANT: The Digital Shower Valve must be accessible and should not be sealed in the wall Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. THERMASOL.COM I 800.776.0711...
Page 19
Digital Shower Valve Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. THERMASOL.COM I 800.776.0711...
Page 20
Digital Shower Valve Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. THERMASOL.COM I 800.776.0711...
Remove Cover Inside Valve System Controller Battery Compartment Power Supply Mounting Holes Connector 15V ACCU Block Cold Outlets Inlets Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. THERMASOL.COM I 800.776.0711...
Page 22
IMPORTANT: The Digital Shower Valve must be installed within 50' of the PDM module. 235mm / 9.25" 235mm / 9.25" 8mm / 0.31" Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. THERMASOL.COM I 800.776.0711...
Page 23
Digital Shower Valve Install Valve System Controller Remove Inlet Retaining Bolt Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. THERMASOL.COM I 800.776.0711...
Page 24
1/2" NPT Connections 3. re-insert retaining bolt IMPORTANT: Flush the pipework before connection Remove Outlet Retaining Bolt Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. THERMASOL.COM I 800.776.0711...
Page 25
2. Insert outlet connectors 1. Connect outlet pipeworks IMPORTANT: Flush the waterlines prior to connecting to clear any debris. Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. THERMASOL.COM I 800.776.0711...
Page 26
Connect Back Up Battery Accu Connect The Digital Interface Connect the digital interface to the RS232 port RS232 Port Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. THERMASOL.COM I 800.776.0711...
Page 27
Digital Shower Valve Connect The PDM Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. THERMASOL.COM I 800.776.0711...
Page 28
Digital Shower Valve Re-fit Cover and Connect IMPORTANT: Electrical connection must be installed by a qualified electrician. Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. THERMASOL.COM I 800.776.0711...
Page 29
ThermaSol Product Registration Dear ThermaSol End User: Please register your product at www.thermasol.com/warranty so we can assist you much quicker if you ever need to contact our Technical Support Department. In addition we’ll keep you informed about your product and time to time we’ll update you about new products and other company announcements.
Page 30
3. ThermaSol does not guarantee that a local service person will be available for in-home services. Unit may have to be removed and reinstalled at owner’s expense. It is the responsibility of the buyer to file a claim with the carrier/carriers for any product that has shipping damage to or from ThermaSol.
Page 31
Digital Shower Valve Notes: Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. THERMASOL.COM I 800.776.0711...
Page 32
Digital Shower Valve 1958 STEAM WAY ROUND ROCK, TX 78665 PHONE: 800.776.0711 | FAX: 800.556.5257 | WWW.THERMASOL.COM 81216 Rev C 12/19...
Page 33
Installation Manual For Tutorials and Troubleshooting visit www.thermasol.com/solutions HVLSRSQ-XX OVER 60 YEARS OF STEAM SHOWER INNOVATION...
Page 34
NEVER ATTEMPT TO FILL AROMA RESERVOIR ON THE STEAMHEAD WHEN UNIT IS IN THE "ON" POSITION. SEVERE BURNS WILL OCCUR. DO NOT USE THERMASOL AROMATHERAPY OILS, SKIN CARE PRODUCTS OR ANY PRODUCT ASSOCIATED WITH YOUR THERMASOL UNIT WITHOUT CONSULTING WITH YOUR ALLERGIST OR DOCTOR BEFORE USE. THESE PRODUCTS MAY BE HAZARDOUS TO YOUR HEALTH.
Page 35
Tile Cutter with shut off valve Joist Mounting Bracket + 4x #4 Flat Head Screw Plywood Waterproof Backing Mortar Finished #10 Flat Head Screw Shower Surface RTV Silicone Sealant O-Ring (-016) Screw Cover (Fig. 1) Installation Profile View THERMASOL.COM 800.776.0711...
Page 36
25' Yellow M12 Cable single ThermaTouch Control. Item 03-7149-25 ThermaTouch Control sold separately 25' Yellow M12 Cable Item 03-7149-25 ships with ThermaTouch control PDM Sold and ships with ThermaTouch control THERMASOL.COM 800.776.0711...
Please be cautious and practice ladder safety. Connecting HydroVive NOTE: Make sure electrical power is off to all ThermaSol devices prior to making any connections. Align the notches at the top of the mounting guides with the mounting brackets and slip them over to firmly secure the HydroVive in place while the connections are made.
NOT OVERTIGHTEN! Once the HydroVive is in position and the silicone seal is created, no further clamping force is necessary. Complete Installation Install the Screw Covers with O-Rings by hand. Allow the silicone to dry for 24 hours before use. THERMASOL.COM 800.776.0711...
Page 39
• Increase the separation between the equipment and receiver • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected • Consult the dealer or an experienced radio/TV technician for help THERMASOL.COM 800.776.0711...
Page 40
1958 STEAM WAY ROUND ROCK, TX 78665 PHONE: 800.776.0711 | FAX: 800.556.5257 | WWW.THERMASOL.COM 81253_A...
Page 41
1958 STEAM WAY ROUND ROCK, TX 78665 PHONE: 800.776.0711 | FAX: 800.556.5257 | WWW.THERMASOL.COM 81282_NC...
Need help?
Do you have a question about the WHSP7S and is the answer not in the manual?
Questions and answers