Adjustment of sensitivity for sensors with EasyTeach function
Empty adjustment - Active surface free
When the adjustment with the product to be detected is not possible, an empty adjustment can be made,
e. g. the product to be detected is not known at the time of the sensor adjustment, but an overfilling must
be excluded. When the level is filled for the first time, we recommend to make a full adjustment so that
the sensor is optimal adjusted on the material to be detected.
• The active surface of the sensor is free.
• Connect the grey teach wire (pin 5) to the supply voltage (U
ing and output A2 pulsates.
• Disconnect the grey teach wire (pin 5).
• During the initialization process the LED is flashing green and A2 pulsates with higher frequency.
The empty adjustment is finished when the LED is static green. With this adjustment the sensor has the
largest sensing distance that is possible at the current mounting position. The switching hysteresis is
calculated automatically.
Full adjustment - Active surface covered
• Immerse the active area into the product to be detected.
• Connect the grey teach wire (pin 5) to the supply voltage (U
yellow and output A1 pulsates.
• Disconnect the grey teach wire (pin 5).
• During the initialization process the LED is flashing yellow with a high frequency and A1 will pulsate
accordingly.
The full adjustment is finished when the LED is static yellow and A1 is high. The sensor is now optimally
adjusted for the detection of the media currently being used and the current mounting conditions. The
switching hysteresis is calculated automatically.
Test
The test function can be used to check the control system that is connected to the sensor.
• Connect the grey teach wire (pin 5) to the supply voltage (U
yellow-green and the outputs switch pulsating at the same time.
Leave the test mode by disconnecting the grey teach wire from the supply voltage. The sensor returns
to the previously adjusted state.
Attention:
i
After making the EasyTeach adjustment, please put the Teach-wire (pin 5) on GND of the
supply voltage (U

Maintenance, repair, disposal

• Maintenance for this device is not necessary when used as intended.
• It is not possible to repair the device. If you have any problems, please contact directly your customer
service.
• Please dispose of the device in a way that is environmentally friendly according to the national
regulations.
-).