    UBC Group www.beer-co.com Table of contents Model type ..................... 3 1. SAFETY ....................4 1.1. GENERAL INFORMATION .............. 4 1.2. LIMITATION OF LIABILITY ............4 1.3. EXPLANATION OF SYMBOLS ............5 1.4. SAFETY INSTRUCTIONS AND WARNINGS........6 2.1. STANDARDS AND DIRECTIVES ............ 8 2.2.
  • Page 3: Model Type

    UBC Group www.beer-co.com Model type Model Volume, External Temperature range, °C dimensions, mm weight WxDxH "Frost Stream" Hermes 1.45 1450x860x950 -18..-23 "Frost Stream" Hermes 1. 85 1850x860x950 -18..-23/ -5..+5 "Frost Stream" Hermes 1. 85 1850x860x820 -18..-23/ (low) -5..+5 "Frost Stream" Hermes 2.1 2100x860x950 -18..-23/...
  • Page 4: Safety

    UBC Group www.beer-co.com 1. SECURITY 1.1. GENERAL INFORMATION This operating manual is part of the equipment and ensures safe and efficient operation. Carefully read this instruction manual before using the equipment, and pass it on to other persons who are entrusted with the operation and maintenance of this equipment.
  • Page 5: Explanation Of Symbols

    UBC Group www.beer-co.com Failure to comply with safety regulations; Improper use; Engagement of untrained operational and service personnel; Unauthorized conversion and technical changes by the customer on his own; Use of spare parts not approved by the manufacturer; Malfunction of the power supply or electrical safety devices.
  • Page 6: Safety Instructions And Warnings

    UBC Group www.beer-co.com Flammable Substances ignite from a slight heating, a small substances fire source Separate Special disposal is not allowed throw away collection of together with the rest of the waste, for electrical and processing requires special conditions. electronic equipment 1.4.
  • Page 7 UBC Group www.beer-co.com • Hot steam and water under high pressure or high temperature can damage electrical insulation, electronic parts and the refrigerant circuit. Therefore, do not use hot steam, high temperature or high pressure water. CAUTION • When loading freezers with products, there is a risk of frostbite.
  • Page 8: Standards And Directives

    UBC Group www.beer-co.com indicated on the climate class label ( Chapter 2.2 ), for which the equipment is intended. • The equipment works immediately after connecting to the electrical network. Any other use is considered inappropriate. • The equipment is intended only for storing frozen products.
  • Page 9: Technical Data

    UBC Group www.beer-co.com ISO 9001:2015; ISO 1400:2015; ISO 45001:2018, IDT. Standards used in the design and manufacture of products: EN ISO 23953-2:2015 2.2. TECHNICAL DATA Fig. 2.2.1. Rating plate When working with the equipment, it is necessary to observe the information on the sign.
  • Page 10: Package And Functions

    UBC Group www.beer-co.com 3. Frequency (Hz); 4. Class of protection (IR); 5. Maximum used power (W); 6. Climatic class of the showcase; 7. Net weight of the showcase (kg); 8. Mass of refrigerant (g) 9. Type of refrigerant; 10. Temperature class inside the showcase;...
  • Page 11: Automatic Defrosting

    UBC Group www.beer-co.com The equipment is suitable for storing prepackaged chilled or prepackaged deep-frozen products. All equipment is delivered ready to work and has its own control unit. The equipment is pre-programmed at the factory. Equipment equipped with a mechanical thermostat is designed for deep...
  • Page 12: Operating And Display Elements

    UBC Group www.beer-co.com Thermostat Display indication Symbol Danfoss ERC112C Danfoss ERC112d VSC The melt water formed in the internal volume of the unit is diverted to a heated bath, where it evaporates. The defrosting process can lead to a slight increase in the temperature on the thermostat indicator.
  • Page 13: Mechanical Thermostat

    UBC Group www.beer-co.com 3.1. MECHANICAL THERMOSTAT The temperature regulator (thermostat) is located on the side of the ventilation grill (Fig. 1). Fig. 3.1.1. The location of the thermostat in the side ventilation grille. Thermostat settings: Level 1: The warmest mode...
  • Page 14 UBC Group www.beer-co.com Control elements are buttons programmed as follows: Button Function Short press: Increasing the set temperature (settings) defrost mode switch Short press: Reduction of the set temperature (settings) defrost mode switch Short press: not used; Long press: Enter the information menu...
  • Page 15 UBC Group www.beer-co.com Fig. 3.1.3: Display indication. According to the display Display indication indication Temperature in volume. Operating mode code The cooling function is active Defrosting is active The evaporator fan is active Emergency signal...
  • Page 16: Electronic Temperature Regulator Eliwell

    UBC Group www.beer-co.com 3.3. ELIWELL ELECTRONIC TEMPERATURE REGULATOR controller is placed on the front panel. Control elements are buttons (Fig. 2), which are programmed as follows: Fig. 3.3.1. Indication and control elements of the controller Eliwell. Control element Functions Increase variable value...
  • Page 17: Unpacking And Installation

    UBC Group www.beer-co.com Press the "Enter" button to display the set value. Changing the set value: Press the "Enter" button. The setpoint value will appear on the display. Press the "Up"/"Down" keys to change the set value. Press the "Enter"...
  • Page 18 UBC Group www.beer-co.com Fig. 4.1.1. The procedure for installing grids. 2. Two longitudinal gratings and end gratings are installed on the left wall of the internal space, they are attached to the longitudinal one (see Fig. 4.1.2) Fig . 4.1.2. Fastening of longitudinal and end gratings.
  • Page 19 UBC Group www.beer-co.com The number of partitions depends on the size of the showcase and the customer 's requirements. Fig. 4.1.3. Installation of partitions. 4. Horizontal grids are installed (Fig. 4.1.4) . They are adjustable in height. Figure 4.1.4. Horizontal bars...
  • Page 20: Location And Assembly Procedure In The "Island" Scheme

    UBC Group www.beer-co.com 4.2. LOCATION AND ASSEMBLY PROCEDURE IN THE "ISLAND" SCHEME 1. Mount the brackets on the back panel (Fig. 4.2.1). Fig. 4.2.1. Placement of brackets. 2. When installing showcases in the "island", observe the minimum distances (see Fig. 4.2.2, a, b).
  • Page 21 UBC Group www.beer-co.com 130 мм. Fig. 4.2.2. a) the minimum distance between the side walls; b) the minimum distance between the rear walls. 3. The panels of the pilasters are installed: the front, the end and the connector of the pilasters to the brackets on the legs of the bonnet (Fig.
  • Page 22 UBC Group www.beer-co.com 4. The end insert is installed on the bracket and fixed from below with screws to the file connector (Fig. 4.2.4). Figure 4.2.4. End insert. 5. A trapezoidal cover is installed on the brackets, a plug is installed on top and between them (Fig.
  • Page 23: Loading

    UBC Group www.beer-co.com 6. On the end showcases, a plastic overlay is mounted, and then the panels of the dustpans are installed and connected to other showcases (Fig. 4.2.6). Fig. 4.2.6. Decorative overlay. 5. LOADING The equipment can be loaded with the product only after reaching the temperature corresponding to the storage conditions of the product.
  • Page 24: Decommissioning And Storage

    UBC Group www.beer-co.com The specified storage temperature of the product above the loading line is not guaranteed. 6. DECOMMISSIONING AND STORAGE. Decommissioning should be performed only by qualified service personnel. Decommissioning procedure: 1. Move the product to another equipment with a suitable temperature regime.
  • Page 25 UBC Group www.beer-co.com 5. Remove the melted water. 6. Remove any remaining product that has been stored 7. Wash the equipment using the manufacturer's recommended detergents and equipment. 8. Wipe the device dry. 9. Put back the baskets or partitions.
  • Page 26: Disposal

    UBC Group www.beer-co.com 8. DISPOSAL Improper disposal harms the environment. • Pay attention to the safe disposal of refrigerant, insulating foam (polyurethane foam), compressor oil, power supply unit. • Dispose of the equipment properly in accordance with applicable national disposal regulations and the regulations of your local disposal partner.
  • Page 27 UBC Group www.beer-co.com Authorized service Poland: UBC Logistyka Sp. z o. o Bosnia : NICROM COOLING DOO BYKOW, UL. GAJOWA 5 Milana Vrhovca 79, 79101 55-095 MIRKOW Prijedor, Republika Srpska, Bosnia and Wojtek Rytkowski Herzegovina tel.: +48717400076 / tel. kom.:...
  • Page 28 Duško Rađen RO: str Topliţa, nr. 155, Miercurea Ciuc te+381654977001 Csaba Balint dusko.radjen@coolbeer.co.rs phone: +40266317827 e-mail: csbalint@tcromania.com Ukraine: UBC Service Kazakhstan: UBC Service Address: Kharkiv, Selyanka 110, Address: ZHETUSU AUDANA, PRO. Ukraine Suyinbai, 2, phone: +77777767010 Contact person: Andriy Maydan e-mail: almaty@beer-co.com...