Installation Procedure
Thickness of the wire (mm²)
2.5
4.5
6.0
10.0
Connecting the cable to the power terminal
Connect the cables to the terminal board with the ring
terminals.
NOTE
Be sure to use the certified and rated cables and firmly
connect them without applying any external force to
the ring terminal.
Connect with a driver and wrench that can apply the
rated torque to the screws.
Connect the terminal screws in compliance with the
rated tightening torques.
If the terminal is loose, a fire may occur, caused by
arcing electricity. If the terminal is connected too
firmly, the terminal may be damaged.
Screw
M3
M3.5
M4
M5
M6
R
S
Solderless ring
terminal
When connecting two cables to a ring terminal, separate the ring terminal
up or down to prevent it from getting loose. Place the thin cable upward
and the thick cable downward. Fix the power cables with a cable tie.
14 English
B (mm)
d2 (mm)
Less than 9.5
More than 4.5
Less than 9.5
More than 4.5
Less than 9.5
More than 4.5
Less than 15
More than 8.4
5 to 7.5
8 to 12
12 to 18
20 to 30
25 to 37.5
T
N
Cable tie
Thin cable
Thick cable
Connecting the cables
AC100BXPDKH
This product uses a single phase power, with 220 to
240V supply.
When connecting the outdoor-to-indoor power cables,
be sure to match the numbers (or letters) between the
outdoor and indoor units. Connect the communication
cable to the connector included in the electrical
component box for each unit. When the outdoor-
to-indoor power cables are connected incorrectly, a
malfunction of the product may occur.
When connecting the communication and outdoor-to-
indoor power cables, make sure these cables do not
touch the service valve on the refrigerant pipe on the
gas side or the pipes without proper insulation. Fix the
outdoor-to-indoor power cables to the insulated pipes.
Be sure to comply with the wiring standards, as there
may be a risk of fire.
Make sure to install the circuit breaker firmly inside the
electrical component box.
Entire system diagram
Communication cable
Outdoor-to-indoor power cable
Electrical panel
Main power cable
NFB Single
phase 220 to
240V, 50 Hz
ELB
Outdoor unit
Power wiring diagram
Outdoor-to-indoor
power cable
power supply cable (Single phase AC 220-240V,
should be purchased on-site)
Earthing
Ground wire
Indoor unit
1(L) 2(N) L
N
F1
F2
Cable tie
Communication
cable