Closed system
The condensate ends up in the boiler (A) through a down going
condense return line (C). The waterlevel of the boiler (A) has to
be lower than the lowest condensate output of the connected
machines!
There will be no loss of energy. The energy savings in regard to
the open system is approximately 33%.
This system gives the lowest installationcosts. When the system
works well, the system will work well for years.
Half open system
This system is conform the open system. The only difference is
that in this system at the end of the ringline (B,C) a steamtrap
has to be mounted. This steamtrap brings the condensate in a
watertank (E). The condensate in the watertank (E) will be
pumped in the boiler (A) through the pump (F). In this system
the waterlevel in the boiler (A) can be higher than the
condensate output of the connected machines.
The energy saving in regard to the open system is
approximately 20%.
This system will opperate fault free for years.
A :
Boiler
B :
Steam supply line
C :
Condensate return line
5.2.3
Vacuum
• Connect the press with a 2" gas pipe to the main vacuum line (D). The connection is on the left of
the press, under the table.

6 Put into operation

Think of your own and other people's safety!
Creat a clean, surveyable and spacious working environment.
Make sure that nobody is standing behind the machine.
Check the following points daily!
It is possible that in view of transport, the centre footpedal (7) of de press has been removed. If so,
mount pedal as follows:
Place pedal (A) around pedal rod (B). Be sureto place the lip of the pedal under roll (C) of the latch lever (D). The
mount shaft (E) and cotter.
D :
Steamtrap
E :
Watertank
F :
Pump
G :
Work room
H :
Boiler room
M :
Machine