Model
SA–98S5
240V Single Phase 50Hz
RATING CAPACITY
AIR FLOW RATE
EVAPORATOR
ENT. TEMP. °C
W.B.
15
17
19
21
23
TC :
SHC : Sensible Heat Capacity (kW)
CM : Compressor Input (kW)
Rating conditions (#Mark) are
2.55 kW
360 m
D.B.
20
TC
2.57
CM
0.64
21
SHC
1.65
23
SHC
1.82
25
SHC
1.99
27
SHC
2.16
29
SHC
2.33
31
SHC
2.50
TC
2.76
CM
0.65
21
SHC
1.47
23
SHC
1.64
25
SHC
1.81
27
SHC
1.98
29
SHC
2.15
31
SHC
2.32
TC
2.93
CM
0.67
21
SHC
1.28
23
SHC
1.45
25
SHC
1.62
27
SHC
1.80
29
SHC
1.97
31
SHC
2.14
TC
3.11
CM
0.69
23
SHC
1.26
25
SHC
1.43
27
SHC
1.60
29
SHC
1.77
31
SHC
1.94
TC
3.30
CM
0.71
25
SHC
1.23
27
SHC
1.40
29
SHC
1.57
31
SHC
1.74
Total Cooling Capacity (kW)
Outdoor Ambient Temp. 35°C D.B.
Indoor Unit Entering Air Temp. 27°C D.B. / 19°C W.B.
3
/h
CONDENSER
OUTDOOR AMBIENT TEMP. °C
25
30
2.46
2.35
0.69
0.74
1.58
1.52
1.75
1.69
1.92
1.86
2.09
2.03
2.26
2.20
2.43
2.35
2.64
2.52
0.71
0.76
1.41
1.34
1.58
1.51
1.75
1.68
1.92
1.86
2.09
2.03
2.26
2.20
2.81
2.68
# 2.55
0.73
0.78
1.22
1.16
1.39
1.33
1.56
1.50
1.73
1.67
1.90
1.84
2.07
2.01
2.97
2.84
0.75
0.80
1.20
1.14
1.37
1.31
1.54
1.48
1.71
1.65
1.88
1.82
3.16
3.01
0.77
0.82
1.16
1.10
1.33
1.27
1.51
1.44
1.68
1.61
15
35
40
45
2.23
2.10
1.93
0.79
0.89
0.98
1.46
1.39
1.30
1.63
1.56
1.47
1.80
1.73
1.64
1.97
1.90
1.81
2.14
2.07
1.93
2.23
2.10
1.93
2.40
2.25
2.07
0.81
0.91
1.01
1.28
1.21
1.12
1.45
1.38
1.29
1.62
1.55
1.46
1.79
1.72
1.63
1.96
1.89
1.80
2.13
2.06
1.97
2.40
2.21
0.84
0.94
1.04
1.09
1.02
0.94
1.27
1.19
1.11
1.44
1.36
1.28
1.61
1.53
1.45
1.78
1.70
1.62
1.95
1.88
1.79
2.70
2.54
2.34
0.86
0.96
1.06
1.07
1.00
0.92
1.25
1.17
1.09
1.42
1.35
1.26
1.59
1.52
1.43
1.76
1.69
1.60
2.84
2.66
2.47
0.88
0.99
1.09
1.03
0.96
0.89
1.20
1.13
1.06
1.37
1.30
1.23
1.54
1.47
1.40