Fujitsu AUXG07-14KVLA Design & Technical Manual page 116

Air conditioner 2-unit multi-split type
Table of Contents

Advertisement

Type
Model name
ASYG07KGTB
ASYG09KGTB
ASYG12KGTB
ASYG14KGTB
ASYG07KGTE
ASYG09KGTE
ASYG12KGTE
ASYG14KGTE
ASYG07KMTB
ASYG09KMTB
ASYG12KMTB
ASYG14KMTB
ASYG07KMCC
ASYG09KMCC
ASYG12KMCC
ASYG14KMCC
ASYG07KMCE
ASYG09KMCE
Wall mounted
ASYG12KMCE
ASYG14KMCE
ASYG07KETA
ASYG07KETA-B
ASYG09KETA
ASYG09KETA-B
ASYG12KETA
ASYG12KETA-B
ASYG14KETA
ASYG14KETA-B
ASYG07KETE
ASYG07KETE-B
ASYG09KETE
ASYG09KETE-B
ASYG12KETE
ASYG12KETE-B
ASYG14KETE
ASYG14KETE-B
AGYG09KVCA
Floor
AGYG12KVCA
AGYG14KVCA
MCA: Minimum Circuit Ampacity = Maximum operating current (Full load)
FLA: Full Load Amperes (Fan motor)
Power supply
Indoor rated
(50 Hz, 230 V)
Input
MCA
power
(A)
(W)
0.25
23
0.30
27
0.30
27
0.37
33
0.25
23
0.30
27
0.30
27
0.37
33
0.25
23
0.30
27
0.30
27
0.38
33
0.25
23
0.30
27
0.30
27
0.38
33
0.25
23
0.30
27
0.30
27
0.38
33
0.25
23
0.30
27
0.30
27
0.38
33
0.25
23
0.30
27
0.30
27
0.38
33
0.19
16
0.23
20
0.25
23
- 110 -
Wiring spec. of connection
cable
(Indoor unit to outdoor
unit)
Cross-
FLA
sectional
area
2
(A)
(mm
)
0.20
0.24
0.24
0.29
0.20
0.24
0.24
0.29
0.20
0.24
0.24
0.30
0.20
0.24
0.24
0.30
0.20
0.24
1.5
0.24
0.30
0.20
0.24
0.24
0.30
0.20
0.24
0.24
0.30
0.15
0.18
1.5
0.20
9. Electrical characteristics
Limited
wiring
length
(m)
21