Download Print this page

Dimplex DXLAT75w Installation And Operating Instructions page 3

Skirting heaters

Advertisement

Key Lock:
If 'ENTER' and 'MODE' are pressed within 1 second, the keys will
be locked. The user will know the keys are locked as the lock
symbol ' ' will be displayed on the top left hand corner of the
screen. To unlock the keypad, press 'ENTER' and then 'MODE'
within 1 second.
Initial Operation
For initial use, plug the heater into a regular household power
point and turn the power on. The timer is now ready to be set up
for use.
ON
P1
OFF
AUTO
Setting Current Time
1. Press the 'PROGRAM' button ONCE. The clock symbol
appears on the top left hand side of the screen. The user can
now set the clock.
2. The hour digit will flash. To adjust the hour use the '-' & '+'
buttons. Confirm the hour digit by pressing 'ENTER'.
3. Once 'ENTER' has been pressed the minutes will flash. To
adjust the minutes use the '-'&'+' buttons. Confirm the minute
digit by pressing 'ENTER'.
4. The timer now returns to the default display.
5. To reset incorrect time, repeat previous steps.
Once the correct time is set, a total of four ON/OFF time programs
can be set for operation. There are two program options.
Setting Programmes
Press the 'PROGRAM' key twice to set the programs.
You are now setting the programs starting with P1 'ON'.
SETTING P1 ON TIME:
1. To set the hour use the '-' & '+' buttons. Confirm the hour digit
by pressing 'ENTER'.
2. To set the minutes use the '-' & '+' buttons. Confirm the minute
digit by pressing 'ENTER'.
Note: The minutes can only be set in 10 minute blocks in
programme 'MODE'.
SETTING P1 OFF TIME:
3. To set the hour use the '-' & '+' buttons. Confirm the hour digit
by pressing 'ENTER'.
4. To set the minutes use the '-' & '+' buttons. Confirm the minute
digit by pressing 'ENTER'.
Repeat steps 1 to 4 to programme P2, P3 & P4. After programming
P4 'OFF' you automatically exit to the default display.
At any time while programming the timer you can press the
'PROGRAM' button to exit to the default display.
The Advance Function
When in 'AUTO' MODE, if the '+' button is pressed for longer than
2 seconds the programme will ADVANCE to the next setting
programmed and will only revert back to the program when the
subsequent programme time is reached. When the 'ADVANCE'
function is running the 'ADVANCE' segment will be displayed on
the LCD screen. If the '-' button is pressed when the 'ADVANCE'
programme is running the 'ADVANCE' feature will be automatically
cancelled and the programme will run as normal.
Note - Timer Memory Back Up Batteries - Once the heater has
been left plugged in with the socket switched on for at least 72
hours the timer's memory back up batteries will be fully charged.
13 : 17
ADVANCE
MAN
ON
Fig. 8
Once the timer batteries are fully charged, if there is a power cut
or if the heater is disconnected from the mains for less than six
months, then the timer will continue to keep time & the settings in
the memory will remain intact.
Safety – overheat protection
For your safety, this appliance is fitted with a thermal cut-out. In
the event that the product overheats for some reason, the cut-out
prevents excessive temperatures on the product by cutting the
power to the heater. Once the heater has cooled down, it will
reset automatically, it will continue to cycle on and off automatically
until the reason for overheating has been removed.
Important Notes
Although this heater is manufactured to comply with the relevant
safety standards, certain types of carpets could become
discoloured by the temperatures under a portable heater. If you
are concerned about this, we recommend that you contact the
carpet manufacturer for guidance. Alternatively, either stand the
heater on a suitable base to shield the carpet – call our Helpline
for further advice.
You may notice some parts of the element appearing to be hotter
from time to time because of the variable airflow through the
heater. This does not cause a safety hazard.
The heat outlet grille may become discoloured with use – this is
caused by airborne pollution and is not a fault.

Advertisement

loading

This manual is also suitable for: