Dimplex Low Wattage Panel Heaters
Models: DXLWP400, DXLWP400TI,
DXLWP800, DXLWP800TI N & ARLWP800TI
Dimensions
(millimetres)
Models
Specification
DXLWP400
400W Neon Heat Switch
DXLWP400TI
400W Neon Heat Switch / 24 Hour Timer
DXLWP800
800W Neon Heat Switch
DXLWP800TI N
800W Neon Heat Switch / 24 Hour Timer
ARLWP800TI
800W 2 Neon Heat Switches / 24 Hour Timer
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
Important Safety Advice
WARNING –THIS APPLIANCE MUST NOT BE USED IN A
BATHROOM.
WARNING - DO NOT USE THIS HEATER IN THE IMMEDIATE
SURROUNDINGS OF A BATH, A SHOWER OR A SWIMMING
POOL.
WARNING – THIS HEATER MUST NOT BE LOCATED
IMMEDIATELY BELOW A FIXED SOCKET OUTLET.
The plug must be accessible after heater installation.
DO NOT USE THE HEATER UNTIL THE FEET OR WALL
BRACKETS ARE FITTED CORRECTLY.
FOLLOW these instructions carefully.
The heater carries a warning 'DO NOT COVER' to alert the
user to the risk of fire that exists if the heater is
accidentally covered.
Models DXLWP400TI, DXLWP800TIN and ARLWP800TI
can be set to switch on automatically. Remember to
observe all safety warnings at all times.
This appliance is not intended for use by children or other
persons without assistance or supervision if their
physical, sensory or mental capabilities prevent them
from using it safely. Children should be supervised to
ensure that they do not play with the appliance.
If young children, the aged or infirm are likely to be left in
the vicinity of the heater, we advise that adequate
precautions should be taken. We recommend a guard
be fitted to ensure contact with the heater is avoided and
objects cannot be inserted into the product.
If the mains lead is damaged, it must be replaced by the
manufacturer or its service agent or a similarly qualified
person in order to avoid a hazard.
For further information, please contact our guard supplier
direct on Tel. No. 01603 667957, or in case of difficulty or
for further advice contact the Customer Helpline.

Installation and Operating Instructions

600 mm - 400W
800 mm - 800W
Electrical Connection
WARNING THIS APPLIANCE MUST BE EARTHED
If the socket outlets in your home are not of the 13 amp BS1363
type they will not accept the plug connected to this heater, therefore
cut off the plug. When cut off this plug can constitute a shock
hazard if inserted into a socket outlet. It must therefore be
disposed of safely.
Before wiring the appropriate plug please note that the wires in
this mains lead are coloured in accordance with the following
code.
GREEN/YELLOW:
BLUE:
BROWN:
Connect the Green/Yellow wire to the terminal marked E or the
earth symbol
or coloured Green or Green/Yellow.
Connect the Brown wire to the terminal marked L or coloured
Red.
Connect the Blue wire to the terminal marked N or coloured
Black.
DO NOT connect the Brown (Live) or the Blue (Neutral) wires to
the Earth terminal of your 13 amp plug. If the terminals of the
plug are unmarked or you are in any doubt, consult a qualified
electrician.
CAUTION: If you use this heater in conjunction with a thermal
control, programme controller, timer or any other device which
switches the heater on automatically observe all safety warnings
at all times.
INDUKLWPRG
500 mm
EARTH
NEUTRAL
LIVE
Issue 6

Advertisement

loading

Summary of Contents for Dimplex ARLWP800TI

  • Page 1: Installation And Operating Instructions

    Dimplex Low Wattage Panel Heaters Models: DXLWP400, DXLWP400TI, DXLWP800, DXLWP800TI N & ARLWP800TI Dimensions (millimetres) Models Specification DXLWP400 400W Neon Heat Switch DXLWP400TI 400W Neon Heat Switch / 24 Hour Timer DXLWP800 800W Neon Heat Switch DXLWP800TI N 800W Neon Heat Switch / 24 Hour Timer...
  • Page 2: Positioning The Heater

    Turn the heater on using the switch on the right side of the heater - the switch will be illuminated. OPERATION - DUAL RATED MODEL - Model ARLWP800TI The two switches on the side of the heater control the heat output.
  • Page 3 Models with Timer DXLWP400TI, DXLWP800TI N & ARLWP800TI Set the I - (Fig. 3) to : Position O - Heating Off Position I - Manual operation This setting allows power to the heater uninterrupted by the timer settings. The heat selector switch will control the output (see ‘Using the heater’).
  • Page 4 [c] Glen Dimplex UK Limited All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of Glen Dimplex UK Limited. UK customer help line (8.00AM – 6.00PM Mon-Fri; 8.30AM-1.00PM Sat) Customer Services: Tel.