Download Print this page

NORPOLE NP1R-SW Manual page 7

Advertisement

:
NOTE
It is not recommended to change the default operating parameters for the temperature and
defrost settings, or other advanced settings within the controller. If adjustments to these settings are
needed, please contact customer service or a qualified service technician.
TURNING THE UNIT ON AND OFF
Make sure that the main power switch next to the control panel is in the On position, then press and hold
the UP-ON/Off button (
SETTING THE TEMPERATURE
To adjust the set temperature, follow the instructions below:
1.
Press SET (
2.
Use the UP (
The temperature can be set with a range of 32°f (0°C) to 41°f (5°C).
3.
Press SET (
The unit will now cool to the set temperature.
:
NOTE
Setting the temperature control too low may result in the evaporator coil building up excessive
ice which can lead to the refrigerator not cooling properly.
DEFROSTING
When the compressor is not running, the evaporator fans continue to circulate air through the evaporator
coil, melting accumulated frost. The water will drain into a drain pan to be evaporated. There is also an
automatic electric defrost system to keep ice from building up on the cooling system. The defrost cycle is
set to operate for a preset amount of time at preset intervals. To manually start a defrost cycle, press and
hold the DOWN-DEFROST button (
:
NOTE
Opening the door often, or for long periods can cause excessive ice buildup and higher
temperatures in the cabinet, and should be avoided.
:
NOTE
The manual defrost will only happen if the temperature is within the defrost parameters.
CONTINUOUS CYCLE
To set the unit to run in a continuous cycle, press the UP (
for 3 seconds.
:
NOTE
It is not recommended to put the unit into the Continuous Cycle mode as doing so may result in
the evaporator coil building up excessive ice which can lead to the refrigerator not cooling properly.
LOADING PRODUCT
Before loading product onto the pre-installed shelves, make sure that all the shelf clips are securely
fastened, and that the shelves are stable and level. In order to maintain proper airflow in the refrigerator, be
sure to leave 2-4" of clearance between the back wall and product stored in the unit. Blocking the evaporator
fans may result in the cabinet not cooling properly, and can lead to compressor failure. Always allow the
unit to cool down to the set temperature before loading product into it.
:
NOTE
After unplugging the unit, ALWAYS wait at least 10 minutes before plugging it back in. failure to
do so could result in damage to the compressor.
) for 3 seconds to turn on or off.
) button for 1 second. The set temperature will start flashing after a few moments.
) or DOWN (
) buttons increase or decrease the desired temperature setting.
) button to confirm the set temperature and save the setting.
) for 3 seconds.
) or DOWN (
7
) buttons simultaneously

Advertisement